f [Hz]
200
100
1000
f [Hz]
200
50
200
150
f [Hz]
200
0
150
100
P03
Commissioning
5–3
1070 066 028-101 (01.05) GB
5.1.2
Output frequency
P01 (A-0-0001)
Setting the output frequency range
Selection of the working range which must comprise all further frequency
settings.
factory
setting
all
DMs,
DS
E0.1
(0.1)
up to
100
E0.2
(0.2)
up to
200
E0.3
(0.3)
up to
300
E0.4
(0.4)
up to
400
E0.5
(0.5)
up to
500
E0.6
(0.6)
up to
600
E0.7
(0.7)
up to
700
E0.8
(0.8)
up to
800
E0.9
(0.9)
up to
900
E1.0
(1.0)
up to
1000 Hz
P02 (A-0-0002)
Maximum output frequency
Selection of the precise maximum admissible output frequency
50
999 Hz
smallest step
Range [Hz]
factory
setting
all
DMs, DS
150
0.1
1
100
limits
<
=
min.
max.
f
clock
9
<
=
P03 (A-0-0003)
Minimum output frequency
Selection of the lowest admissible output frequency
0.0
100 Hz
smallest step
Range [Hz]
factory
setting
all
DMs, DS
0.1
limits
<
=
min.
max.
If P02 is subsequently set to values lower than P03, P03 is changed
accordingly, assuming the same value.