11
9. Choose Venting Option
The hood can be set to vent outside or to
recirculate air back into the kitchen.
The plastic vent lever is located near the center
of the hood opening.
To vent to the outside, make sure the plastic
vent lever is in the HORIZONTAL position (flat
against the metal top of the hood).
To recirculate air into the kitchen, make sure
the plastic vent lever is in the VERTICAL
position (flat against the plastic blower housing).
NOTE: In order to change the vent lever
position, you will need to pull the lever out
slightly to clear the plastic tabs.
10.For recessed bottom cabinet only
If the cabinets have front, side or back trim,
make 2 wood shims the width of the trim and
attach them to the cabinet bottom recess on
both sides. See previous page for marking
locations.
11.Cut holes at marked locations for duct and
electrical wiring. For the vertical duct, cut out 3/
4” extra toward the front of the cabinet so you
can move the duct freely when installing the
hood.
It may also ease installation by cutting the hole
10 1/2” instead of 10”.
12.Drive a mounting screw (from the hardware
packet) partway into each center of the narrow
neck of the keyhole slots marked on the cabinet
bottom.
13.Fix the wiring conduit to the hood.
14.Slide the hood back against the wall. Tighten
the mounting screws. Be sure the screw heads
are in the narrow neck of the keyhole slot.
Connect Ductwork to hood.
15.WIRING THE HOOD
WARNING
Electrical Shock Hazard
Warning: Turn off power at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN
ELECTRICAL JUNCTION BOX WITH 3 WIRES,
ONE OF WHICH (GREEN/YELLOW) SERVES TO
GROUND THE APPLIANCE. TO PROTECT YOU
AGAINST ELECTRIC SHOCK, THE GREEN AND
YELLOW WIRE MUST BE CONNECTED TO THE
GROUNDING WIRE IN YOUR
HOME ELECTRICAL SYSTEM, AND IT MUST
UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Set for
outside venting
Set for
recirculating
Stop tab
Stop tab
Hood shown Lying upside down
Failure to do so can result in death or electrical
shock.
•
If not already done, install 1/2” conduit
connector in j-box.
•
Run black (live), white (neutral), and green
(earth) wires (#14 AWG) according to the
National Electrical Code or CSA Standards and
local codes and ordinances in 1/2” conduit from
power supply to j-box.
•
Connect black, white, and green wires from
power supply to black (live), white (neutral), and
green/yellow (earth) wires in j-box respectively.
•
These connections should be done always
making reference to the electrical diagram
found inside the hood.
•
Close j-box cover.
Final installation steps
16.Replace filters as described in the Care & Use
section of this manual.
Models DUH30252UC and DUH36252UCOnly:
Install the lamps on proper housings.
Note: Lamps are not supplied, use ONLY 120
Volt, 50 Watt (maximum) 50° halogen light
made for a GU10 base, suitable for use in
open luminarie.
Turn power on at service panel. Check
operation of the hood.
Wood shims