RAID Subsystem DVA-08K | Installation Manual
Introduction | en
13
Bosch Security Systems
F.01U.027.797 | V1 | 2006.05
•
Ethernet Port
All controller modules on the subsystems come with a single 10/100BasedT RJ-45 Ether-
net port. The Ethernet port is used for local or remote management through the network
using the Bosch RAIDWatch GUI manager or Telnet protocol.
•
COM Port
All controller modules come with one RS-232C (audio jack) serial port. The serial port is
used for local access to the system-embedded configuration utility over the included
serial port cable.
DIMM Module
The controller module comes with a preinstalled 256MB capacity or above DDR RAM DIMM
module and can support a larger capacity up to 2GB. The DIMM module is mounted in an eas-
ily accessible location on the controller board. However, when the DIMM module is being
changed, the controller module must be removed from the subsystem chassis.
2.3.4
Battery Backup Unit
The Li-ION battery backup unit (BBU) module sustains cache memory for days after a power
failure. It is installed on the upper left corner of the controller module in the rear of subsystem
Section 3 Hardware Installation
for installation details.
Fig. 2.11
BBU Module
In accordance with international transportation regulations, the BBU module is only charged
to between 35% and 45% of its total capacity when shipped. Therefore, when powering on the
subsystem for the first time the BBU will begin to charge its batteries to their full capacity. It
normally requires approximately twelve (12) hours for the battery to be fully charged. If the
battery is not fully charged after twelve (12) hours (its LED is still flashing), there is a problem
with the BBU module and you should contact your subsystem vendor immediately. While the
battery is being charged, the LED on the BBU rear panel and the fifth LED on the controller
module will flash.
You can check the status of the battery’s charge via Bosch RAIDWatch Manager or the firm-
ware utility screen.
2.3.5
Power Supply Units
The SATA-based RAID subsystems are equipped with two (2) redundant, hot-swappable, 2U,
350W power supply unit (PSUs) modules. The PSU is permanently mounted into a 2U high
i
NOTICE!
This subsystems come with preset configurations for channel mode and channel ID settings,
and should be sufficient for most applications.
Summary of Contents for DVA-08K
Page 1: ...RAID Subsystem DVA 08K DVA 08K SCSI Premium Series en Installation Manual ...
Page 2: ......
Page 61: ......