40
en | Subsystem Maintenance
RAID Subsystem DVA-08K | Installation Manual
F.01U.027.797 | V1 | 2006.05
Bosch Security Systems
6.3.3
DIMM Module Installation
If a DIMM module fails or a DIMM module with a higher memory capacity is required, the
DIMM module must be replaced.
1.
Remove the controller module.
2.
Remove the previously installed DIMM module from the DIMM socket. To do this, push
the white module clips on the sides of the DIMM module down together. By doing this,
the previously installed modules will be ejected from the DIMM socket. (See
)
Fig. 6.2
Push Back the Module Clips on the Sides of the DIMM Socket
3.
Gently retrieve the DIMM module out of the DIMM socket. (See
4.
Insert the DIMM module into the DIMM socket. Align the DIMM module with the DIMM
socket. Once aligned, gently push the DIMM module into the socket. The white clips on
the sides of the socket will close automatically and secure the DIMM module into the
socket.
Fig. 6.3
Insert the DIMM Module
5.
Reinstall the controller module. After the DIMM module has been properly installed, the
controller module must be reinstalled. To do this, align the controller module with the
controller module bay. Then gently push the controller module in the controller bay.
Carefully push the controller until you feel the contact when the board edge connectors
are mated to the backplane. Do not use force. If unusual contact resistance is felt, try it
again. Next secure the controller module into the subsystem by fastening the hand
screws on the sides.
CAUTION!
The pre-installed modules must be removed prior to installing new memory modules. Do this
with care. Sensitive components can be damaged during the process.