48
en | Appendix: Technical Specifications
RAID Subsystem DVA-08K | Installation Manual
F.01U.027.797 | V1 | 2006.05
Bosch Security Systems
7.1
Controller Specifications
7.1.1
Configuration
Safety Requirements
UL
CB
Shock
Half-sine
Operating: 5G peak, 11ms duration
Non-operating: 15G, 11ms, half-sine
Vibration
Operating
0.5oct/min
Non-operating
0.5oct/min
Warning Alarms
•
LCD screen messages
•
Audible alarms
•
System LEDs
•
Event notification via the Bosch RAIDWatch Manager (LAN broadcast, email, fax,
MSN, ICQ, SMS, and SNMP traps) and RS-232C terminal display
Specifications
RAID Levels
0, 1(0 + 1), 3, 5, 10, 30, 50, JBOD, and non-RAID disk spanning
Host OS Compatibil-
ity
Host OS independent; supports all major platforms
Host Interface
2 SCSI-320 channels via 2 dual-stacked VHDCI connectors
Host Channels
2 pre-configured SCSI-320 host channels
Drive Interface
Supports 8 channel connection to 3Gbps SATA-II disk drives,
SATA-I backward compatible
Drive Channels
All drive channels are pre-configured, routed through a back-end
PCB and cannot be changed