RAID Subsystem DVA-08K | Installation Manual
Appendix: Technical Specifications | en
51
Bosch Security Systems
F.01U.027.797 | V1 | 2006.05
7.5
RAID Management
Input Power
9/3.12W max.
Rated Voltage
DC 12V
Temperature
Operating: -10 to +60ºC
Storage: -20 to +70ºC
Specifications
Specifications
Configuration
LCD keypad panel
Text-based firmware-embedded utility over RS-232C connection
through the included audio jack-to-DB-9 serial cable
The Bosch RAIDWatch Manager program using Ethernet connec-
tion
Performance Monitor-
ing
Yes
Remote Control and
Monitoring
Yes
Event Notification
Yes (via Bosch RAIDWatch’s sub-modules, Configuration Client
or NPC)
Management Connec-
tion
In-band over Ethernet, or RS-232C
Configuration on Disk
Configuration data stored on disk drives for logical drive assem-
blies to exist after controller replacement; basic settings, e.g.,
channel mode settings, are stored on NVRAM
Failure Indicator
Via audible alarm, LCD keypad panel, Bosch RAIDWatch Man-
ager session, event notifications, or event prompts on terminal
emulation