RAID Subsystem DVA-08K | Installation Manual
Subsystem Connection and Operation | en
33
Bosch Security Systems
F.01U.027.797 | V1 | 2006.05
5.3
Host Connection Topology
Fig. 5.2
Cascaded Subsystems Connected to Two Host Computers
, the SCSI ports are connected to different host computers.
This provides both path and host computer redundancy. If one of the host channels becomes
disconnected, or if the cable connecting one of the host ports to the host computer is dam-
aged, the second path can transmit data from the subsystem to one of the host computers.
Similarly, in the clustered hosts configuration, the same array can be accessed through differ-
ent data paths and downtime will be minimized.
To obtain more disk capacity, the “Out” ports are used to cascade another subsystem.
The host-side connection can be made as the following:
1.
Directly to servers or workstations equipped with SCSI HBAs.
2.
Connect two subsystems on the same host buses for a larger combined capacity.
3.
Cross-link the host ports on subsystem(s) to clustered servers.
High availability configurations, such as clustering or redundant paths settings, can be applied
with adequate software control. The same logical array can be associated with two or more
different host IDs to facilitate access down through different HBAs.
Default Channel Settings
5.4
Power On
After installing all the components in the subsystem, connecting the host channels to the
host, and connecting the expansion cables to the expansion enclosures, the subsystem is
ready to be powered on.
5.4.1
Power On Checklist
BEFORE powering on the subsystem, please check the following:
•
Memory module: Memory module has been correctly installed on the controller board.
•
BBU modules: Ensure that the BBU modules have been installed correctly.
Model
Host Channels
Drive Channels
DVA-08K
Channel 0 and Channel 1
Channels 1 to 8, each dedicated to
one connected drive
Table 5.1
Default Channel Settings