30
en | Subsystem Monitoring
RAID Subsystem DVA-16K | Installation Manual
F.01U.027.799 | V2 | 2008.08
Bosch Security System
4.2.8
Cooling Module LEDs
Each cooling module has two (2) red LEDs on the back. Each LED corresponds to a single fan
in the cooling module. (See
Figure 4.7
) When the LED is on, it indicates the fan has failed.
When the LED is off, it indicates the fan is functioning properly.
Fig. 4.7
Cooling Module LEDs and Cooling Fan Locations
The RAID subsystem has a novel approach to stabilizing the temperature within the subsys-
tem: When the intelligent sensors on the backplane detect higher temperature, such as high
ambient temperature or the failure of any cooling or PSU module, the system will turn the
cooling fans to high speed to extract more heat. Once the ambient temperature cools down to
normal or the cooling or PSU modules have been replaced, the cooling fans will return to low
speed.
Color
Status
FLASHING Green
The power supply has not been turned on. The PSU module
LED will blink when the subsystem is connected to a power
source but not yet turned on.
Static Green
The PSU is operating normally and experiencing no problem.
Static Red
The PSU has failed and is unable to provide power to the sub-
system.
OFF
The PSU is not turned on. The PSU module LED will remain off
even if the power cable has been plugged in but the power
switch is not turned on.
Table 4.6
Module LED Definitions
Summary of Contents for DVA-16K SCSI
Page 1: ...RAID Subsystem DVA 16K DVA 16K SCSI Premium Series en Installation Manual ...
Page 2: ......
Page 71: ......