52
en | Subsystem Maintenance
RAID Subsystem DVA-16K | Installation Manual
F.01U.027.799 | V2 | 2008.08
Bosch Security System
7.
Insert the previously removed cooling module into the new PSU module. (See
Section 6.6 Cooling Module Maintenance
.)
8.
Insert the new PSU module into the subsystem. Make sure the ejection handle is in its
down position so that the saddle notches on the lower edges of the handle can lock on to
the edge metal brackets along the chassis inner walls. Push the PSU into the slot and pull
the handle upward to secure the module. (See
Figure 6.16
)
Fig. 6.15
Installing the new PSU Module
9.
Secure the PSU to the subsystem by inserting the retention screw to the PSU. (See
Figure 6.16
)
Fig. 6.16
Fastening the PSU Retention Screw
10. Replace the power cable that connects the PSU module to the main power source.
11. Turn the PSU module on.