4
Menu set-up
When system has been connected as described:
•
Switch power on
•
Allow some time for the system to load.
•
Press the MENU key to enter the MAIN MENU.
When the main menu is displayed you see the different
submenus where the settings can be changed.
To navigate through these menus, turn the Jog Dial
clockwise or counterclockwise to scroll through the
submenus. Press the ENTER key to open a submenu. In
the submenus, continue using the Jog Dial and ENTER
key to scroll through items and values and select them.
To return to the main menu, scroll to the bottom of each
submenu to the MAIN MENU item and select it by
using the ENTER key.
4.1 Main menu
4.2 Clock/Language menu
DATE: Year: 2000~2099 Month: 01~12 Date: 01~31
TIME: Hour: 00~23 Minute : 00~59 Second: 00~59
DATE FORMAT: Set the display order for Year (YYYY), Month (MM)
and Day (DD)
MENU LANGUAGE: English, German, French, Spanish, Italian,
Portuguese, Dutch or Polish.
MAIN MENU: Return to the main menu.
4.3 Normal record menu
SPEED : Select the record speed from 0.1 to 25/30 IPS.
QUALITY: There are six quality levels for recording
LOWER 15 KB
LOW: 20 KB
BASIC: 25 KB
STANDARD: 30 KB
HIGH: 35 KB
SUPERIOR: 40 KB
RECORD TIME: Shows an estimate of the recording time available on
disk for the selected speed and quality.
4.4 Alarm record menu
ALARM OPERATION:
ON : Record when alarm occurs.
OFF : Do not record when alarm occurs.
RECORD SPEED: Recording speed for the duration of the alarm.
The max. recording speed is 50/60 IPS (PAL/NTSC).
The min. recording speed is 0.1 IPS.
RECORD QUALITY: Recording picture quality when alarm occurs.
LOWER: 15 KB
LOW: 20 KB
BASIC: 25 KB
STANDARD: 30 KB
HIGH: 35 KB
SUPERIOR: 40 KB
ALARM-IN TYPE:
N.O. : Normally Open
N.C. : Normally Closed
ALARM-RESET TYPE:
N.O. : Normally Open
N.C. : Normally Closed
MAIN MENU
CLOCK/LANGUAGE >
NORMAL RECORD >
ALARM RECORD >
TIMER >
BUZZER >
ARCHIVE >
SYSTEM SETTING >
CLOCK/LANGUAGE MENU
DATE
2002-04-24
TIME
13:01:02
DATE FORMAT
YYYY-MM-DD
MENU LANGUAGE
ENGLISH
MAIN MENU >
NORMAL RECORD MENU
RECORD SPEED
8 IPS
RECORD QUALITY
STANDARD
RECORD TIME
... HRS
MAIN MENU >
ALARM RECORD MENU
ALARM OPERATION
ON
RECORD SPEED
50 IPS
RECORD QUALITY
STANDARD
ALARM-IN TYPE
N.O.
ALARM-RESET TYPE
N.O.
ALARM DURATION TIME
10 SECS
PRE-ALARM OPERATION
ON
RECORD SPEED
50 IPS
MAIN MENU
>