Bosch Security Systems | 2004-6
DVR1C1161
| Installation Manual | Chapter 4
EN
| 16
ALARM DURATION TIME: Alarm recording starts from the beginning
of alarm and stops at the end of the duration or when alarm
reset is activated. The max. duration is non-stop, the min.
duration is 10 seconds.
PRE-ALARM OPERATION:
ON: Record the picture in pre-alarm recording speed in pre-
alarm period.
OFF: No pre-alarm recording before alarm occurs.
RECORD SPEED: The recording speed in the pre-alarm period.
The max. recording speed is 50/60 IPS (PAL/NTSC).
The min. recording speed is 0.1 IPS.
Note
If the alarm occurs in standby or normal recording
mode, the recording quality is the same as the normal
recording quality. If the alarm occurs in timer recording
mode, the recording quality is the same as the value set
in timer recording quality.
4.5 Timer menu
The monitored image can be recorded automatically by
setting the start and end times in the TIMER MENU.
There are 15 entries where a recording schedule for a
particular day or set of days can be set for the week.
Move to an entry and press enter to select the day.
If you program for example the following:
START 09:00, STOP 23:59
Than recording starts at 09:00:00 and stops at 23:59:59.
To stop a timed recording while it is recording, press
the STOP key to enter the TIMER MENU and change
the SET value to OFF.
WEEK: Selects the day or set of days for the timer.
DLY: every day
WDAY: Monday to Friday
WEND: Saturday and Sunday
Individual days of the week
START: Enter the start time for timer recording.
STOP: Enter the end time for timer recording.
STOP time needs to be later than the START time.
(e.g. START 16.00, STOP 03.00 is not correct
START 16.00, STOP 00.00 is not correct
START 16.00, STOP 23.59 is correct
SPEED: When SPEED FORMAT set by HOUR, the recording speed
can be set from 4/6 (NTSC/PAL) HR to 960HR.
When SPEED FORMAT set by IPS, the recording speed can
be set from 0.1~30/0.1~25(NTSC/PAL)IPS.
QUALITY: There are six recording picture quality levels
LOWER: 15 KB
LOW: 20 KB
BASIC: 25 KB
STANDARD: 30 KB
HIGH: 35 KB
SUPERIOR: 40 KB
SET:
Set ON when using timer recording.
Set OFF when not using timer recording.
In Timer Recording mode, the display shows the Timer
date/time and the Timer recording rate appears under
T.REC.
You cannot change the quality level for continuous
recording. For example:
Seg 1 08:30~17:00
Seg 2 17:00~23:59
Seg 1 and Seg 2 are treated as the continuous recording
08:30~23:59.
If you need to set different quality level, set as follows:
Seg 1 08:30~16:59
Seg 2 17:00~23:59
4.6 Buzzer menu
BUZZER OPERATION:
ENABLE: Select buzzer to be on.
DISABLE: Select buzzer to be off.
Note:
Press Enter button to enable/disable in Record/Playback
mode.
ALARM-IN: ON - the buzzer sounds when the alarm occurs.
RECORD-IN: ON - the buzzer sounds when Record-IN signal is
applied on the Record-IN terminal.
DISK FULL: ON - the buzzer sounds when disk is nearly full 99.7%
VIDEO LOSS: ON - the buzzer sounds when the video signal is lost.
TIMER: ON - the buzzer sounds when timer record occurs.
7,0(50(18
:((.67$57672363(('48$/,7<6(7
681+567$1'$5'2))
021+567$1'$5'2))
:'$<+567$1'$5'2))
:(1'+567$1'$5'2))
'/<+567$1'$5'2))
021+567$1'$5'2))
78(+567$1'$5'2))
)5,+567$1'$5'2))
7+8+567$1'$5'2))
:('+567$1'$5'2))
6$7+567$1'$5'2))
681+567$1'$5'2))
0$,10(18!
%8==(50(18
%8==(523(5$7,21
(1$%/(
$/$50,1
21
5(&25',1
21
',6.)8//
21
9,'(2/266
21
7,0(5
2))
0$,10(18
!
Summary of Contents for DVR1C1161
Page 24: ...Bosch Security Systems 2004 6 DVR1C1161 Installation Manual Chapter 6 EN 24 ...
Page 52: ...Bosch Security Systems 06 2004 DVR1C1161 Manuel d installation Chapitre 6 FR 52 ...
Page 102: ...Bosch Security Systems 2004 06 DVR1C1161 Manual de instalación Capítulo 6 ES 102 ...
Page 152: ...Bosch Security Systems 2004 06 DVR1C1161 Manuale d installazione Capitolo 6 IT 152 ...
Page 201: ......