3

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters 

or water heaters) obtain combustion air 

from the room in which they are installed 

and discharge the exhaust gases into the 

open air through an exhaust gas system 

(e.g. a chimney).
In combination with an activated vapour 

extractor hood, room air is extracted from 

the kitchen and neighbouring rooms - a 

partial vacuum is produced if not enough 

fresh air is supplied. Toxic gases from the 

chimney or the extraction shaft are sucked 

back into the living space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone 

will not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for 

combustion is able to enter through 

openings that cannot be sealed, for 

example in doors, windows, incoming/

exhaust air wall boxes or by other technical 

means.

In any case, consult your responsible 

Master Chimney Sweep. He is able to 

assess the house's entire ventilation setup 

and will suggest the suitable ventilation 

measures to you.
Unrestricted operation is possible if the 

vapour extractor hood is operated 

exclusively in the circulating-air mode.

Risk of fire!

Grease deposits in the grease filter may 

catch fire.

Clean the grease filter at least every 

2 months. 

Never operate the appliance without the 

grease filter.

Risk of fire!

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

Risk of fire!

Hot oil and fat can ignite very quickly. 

Never leave hot fat or oil unattended. 

Never use water to put out burning oil or 

fat. Switch off the hotplate. Extinguish 

flames carefully using a lid, fire blanket or 

something similar. 

Risk of fire!

When gas burners are in operation without 

any cookware placed on them, they can 

build up a lot of heat. A ventilation 

appliance installed above the cooker may 

become damaged or catch fire. Only 

operate the gas burners with cookware on 

them.

Risk of fire!

Operating several gas burners at the 

same time gives rise to a great deal of 

heat. A ventilation appliance installed 

above the cooker may become damaged 

or catch fire. Never operate two gas 

burners simultaneously on the highest 

flame for longer than 15 minutes. One 

large burner of more than 5 kW (wok) is 

equivalent to the power of two gas 

burners.

Risk of burns!

The accessible parts become very hot when 

in operation. Never touch hot parts. Keep 

children at a safe distance.

Risk of injury!

Components inside the appliance may 

have sharp edges. Wear protective gloves.

Risk of injury!

Items placed on the appliance may fall 

down. Do not place any objects on the 

appliance.

Summary of Contents for DWA064W50B

Page 1: ... en Instructions for installation and use Extractor hood ...

Page 2: ...ctly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance may be used by children over the age of 8 years old and by persons with re...

Page 3: ...lter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There...

Page 4: ...npack the appliance and dispose of the packaging in an environmentally responsible manner Environmentally friendly disposal Dispose of packaging in an environmentally friendly manner Operating modes This appliance can be used in exhaust air mode or circulating air mode Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is u...

Page 5: ...ts Observe the information in the table to ensure that the different surfaces are not damaged by using the wrong type of cleaning agent Do not use harsh or abrasive cleaning agents cleaning agents with a high concentration of alcohol hard scouring pads or sponges high pressure cleaners or steam cleaners Wash new sponge cloths thoroughly before use Follow all instructions and warnings included with...

Page 6: ...ase filters loosely in the dishwasher The metal mesh grease filters must not be wedged in By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in a hot soapy solution Clean the filters with a brush and then rinse them thoroughly Leave the metal mesh grease filters to drain Removing metal grease filter 1 Open th...

Page 7: ...remove the metal mesh grease filter Replacing halogen bulbs Note When inserting halogen bulbs do not touch the glass tube Use a clean cloth to insert the halogen bulbs 1 Carefully remove the bulb ring using a suitable tool 2 Pull out the bulb and replace it with a bulb of the same type 3 Insert the bulb cover 4 Insert the mains plug or switch on the fuse again Replacing filament bulbs 1 Lift the b...

Page 8: ...n after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who ca...

Page 9: ...ood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers When conveying the exhaust air official and legal regulations e g state building regulations must be followed Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be con...

Page 10: ...ney flue the electricity supply to the hood must be equipped with a suitable safety switch Risk of fire Grease deposits in the grease filter may catch fire The specified safety distances must be observed in order to prevent an accumulation of heat Observe the specifications for your cooking appliance If gas and electric hobs are operated together the largest specified distance applies Only one sid...

Page 11: ... dia 120 mm ca 113 cm2 Flat ducts should not have any sharp deflections Use sealing strips for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be us...

Page 12: ...the wall 4 Screw on the fixing bracket for the flue duct 5 Screw in 2 securing screws with washers to approx 5 mm ª Installation 1 Attaching and aligning the appliance 2 Mark the hole for the safety screw 3 Remove the appliance once more ª Finishing installation of the appliance 1 Drill an 8 mm Ø hole to a depth of 80 mm for the safety screw and press the wall plug flush into the wall 2 Initially ...

Page 13: ...aching the flue duct Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective foil from both flue ducts 3 Push one flue duct into the other Notes To prevent scratches lay paper over the edges of the outer flue duct to protect the surface Slots of the inner flue duct point downwar...

Page 14: ......

Page 15: ......

Page 16: ...940611 9000773694 9000773694 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Reviews: