background image

Installation instructions

 en

11

 12.4 Secure installation

Follow these safety instructions when in-
stalling the appliance.

WARNING ‒ Risk of poisoning!

Risk of poisoning from flue gases being
drawn back in. Room-air-dependent heat-pro-
ducing appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and dis-
charge the exhaust gases into the open
through an exhaust gas system (e.g. a chim-
ney). With the extractor hood switched on, air
is extracted from the kitchen and the adjacent
rooms. Without an adequate supply of air, the
air pressure falls below atmospheric pressure.
Toxic gases from the flue or the extraction
shaft are sucked back into the living space. 

Always ensure adequate fresh air in the
room if the appliance is being operated in
exhaust air mode at the same time as a
room-air-dependent heat-producing appli-
ance is being operated.

It is only possible to safely operate the ap-
pliance if the pressure in the room in which
the heating appliance is installed does not
drop more than 4 Pa (0.04 mbar) below at-
mospheric pressure. This can be achieved
whenever the air needed for combustion is
able to enter through openings that cannot
be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by
other technical means. An incoming/ex-
haust air wall box alone does not ensure
compliance with the limit.

In any case, consult your responsible chim-
ney sweep. They are able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures
to you.

Unrestricted operation is possible if the ap-
pliance is operated exclusively in circulat-
ing-air mode.

Risk of poisoning from flue gases being
drawn back in.

If an extractor hood with an open-flued heat
production source is installed, the power
supply for the extractor hood must be
provided with a suitable safety switch.

Risk of poisoning from flue gases being
drawn back in.

Do not emit the exhaust air into a smoke or
exhaust gas flue that is in operation.

Do not emit the exhaust air into a shaft that
is used to ventilate installation rooms for
heat-producing appliances.

If the exhaust air is to be conveyed into a
smoke or exhaust gas flue, you must obtain
the consent of the heating engineer re-
sponsible.

WARNING ‒ Risk of suffocation!

Children may put packaging material over
their heads or wrap themselves up in it and
suffocate.

Keep packaging material away from chil-
dren.

Do not let children play with packaging ma-
terial.

WARNING ‒ Risk of fire!

Grease deposits in the grease filter may catch
fire.

The specified safety clearances must be
complied with in order to prevent a build-up
of heat.

Observe the specifications for your cooking
appliances. If the installation instructions for
the cooking appliances specify a different
clearance, the larger of the two must al-
ways be provided for. If gas hobs and elec-
tric hobs are operated together, the largest
specified clearance applies.

The appliance must be installed with no
more than one side directly next to a high-
sided unit or a wall. The distance between
the appliance and wall or high-sided unit
must be at least 50 mm.

Summary of Contents for DWP64 Series

Page 1: ...Register your new device on MyBosch now and get free benefits bosch home com welcome Extractor hood DWP94 DWP74 DWP64 DWP96 DWP76 DWP66 en User manual and installation instructions ...

Page 2: ...x 2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by children aged 8 or over and by people who have reduced physical sensory or mental abilities or inad equate experience and or knowledge provided that they are supervised or have been instructed on how to use the appliance safely and have understood the resulting dange...

Page 3: ...ouse s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance without a grease filter Clean the grease filters regularly Never work with naked flames close to the applia...

Page 4: ...ncorrect cleaning damages the surfaces Follow the cleaning instructions Do not use harsh or abrasive detergents Clean stainless steel surfaces in the direction of the finish only Never clean controls with stainless steel cleaners Condensation that flows back in may damage the ap pliance The air extraction duct must be installed with a gradient of at least 1 from the appliance If you put incorrect ...

Page 5: ...air back into the room If the exhaust air is to be conveyed into a non functioning smoke or ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conveyed through the external wall a tele scopic duct should be used 4 2 Air recirculation mode The air which is drawn in is cleaned by the grease fil ters and an odour filter and conveyed back into the ...

Page 6: ...minium parts in the interior of the appliance may cause explosions Never use highly caustic alkaline or highly acidic cleaning agents In particular do not use commer cial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods WARNING Risk of electric shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or s...

Page 7: ...e recommend cleaning the grease filters every two months WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean the grease filters regularly Requirement The grease filters have been removed 1 Observe the information regarding the cleaning agents Cleaning products Page 7 2 Soak the grease filter in hot soapy water Use special grease solvent for stubborn dirt You can obtain g...

Page 8: ...s Fault Cause and troubleshooting The appliance is not working The mains plug of the power cord is not plugged in Connect the appliance to the power supply The circuit breaker in the fuse box has tripped Check the circuit breaker in the fuse box There has been a power cut Check whether the lighting in your kitchen or other appliances are working The LED lighting does not work Different causes are ...

Page 9: ...mber E Nr and the production number FD of your appliance The contact details for Customer Service can be found in the enclosed Customer Service directory or on our website 10 1 Product number E Nr and production number FD You can find the product number E Nr and the pro duction number FD on the appliance s rating plate Depending on the model the rating plate can be found Inside the appliance remov...

Page 10: ...age in transit and completeness of the delivery 12 2 Safety clearances Comply with the safety clearances for the appliance For Australia and New Zealand the minimum safety clearance above electrical cooktops must be 600 mm 12 3 Appliance dimensions You will find the dimensions of the appliance here ...

Page 11: ...able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat ing air mode Risk of poisoning from flue gases being drawn back in If an extractor hood with an open flued heat production source is installed the power supply for the extractor hood must be provided w...

Page 12: ...y unplug the power cord or switch off the fuse in the fuse box Call customer services Page 9 Incorrect repairs are dangerous Repairs to the appliance should only be carried out by trained specialist staff Only use genuine spare parts when repair ing the appliance If the power cord of this appliance is dam aged it must be replaced by trained spe cialist staff Incorrect installation is dangerous Con...

Page 13: ... width of the extractor hood must correspond at least with the width of the hob To optimally detect the cooking vapours install the appliance in the middle of the hob 12 8 Instructions for the exhaust air pipe The appliance manufacturer does not provide any war ranty for faults attributable to the pipeline Use a short straight exhaust air pipe with as large a pipe diameter as possible Long rough e...

Page 14: ...he piping with an exhaust air pipe dia meter of 150 mm Establishing the exhaust air connection exhaust pipe 150 mm diameter 1 Secure the exhaust pipe to the air pipe connector 2 Establish the connection to the exhaust air opening 3 Seal the joints Establishing the exhaust air connection exhaust pipe 120 mm diameter 1 Secure the reducing connector to the air pipe con nector 2 Secure the exhaust air...

Page 15: ... the outer flue duct to protect the surface Place the lower flue duct on the appliance and pull it slightly apart 6 Use 2 long screws to screw the lower flue duct sec tion tightly to the appliance from below 7 Note Align the flue duct before tightening the 2 screws Screw the lower flue duct to the sides of the retain ing bracket using 2 short screws 8 Carefully remove the towels ...

Page 16: ...ing for help You ll find it here Expert advice for your Bosch home appliances help with problems or a repair from Bosch experts Find out everything about the many ways Bosch can support you www bosch home com service Contact data of all countries are listed in the attached service directory 9001672689 9001672689 020218 en BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY www bosch home...

Reviews: