2:21
E
CONVERTING STEEL TOP REGULATOR:
If the regulator has a steel top as pictured in
$
ig
4 on the previous page
convert the
regulator in the following manner:
A. Remove the regulator access cover if equipped.
Do not remove the
S
ressure
U
egulator or allow it to turn.
B. Remove the plastic dust protector from the cap (
$
g
5). Using a 5/8" wrench,
unscrew the cap from the pressure
gulator (
$
ig
6).
Do not remove the
spring from the regulator.
C. Turn the cap over so the hollow end faces outward. Place the solid end of the cap
into the loop end of the dust protector
&$
ig
7).
D. Replace the cap on the regulator with the hollow end facing out (
$
ig
8).
Do not
over
tighten the cap
. Snap the dust protector over the regulator cap.
E. Attach the LP conversion label as illustrated on page 8
then complete the remaining
steps in the instructions provided with the LP kit.
NOTE:
The pressure regulator cap may be made of brass or aluminum depending on
the age of the product. The conversion process is the same for both types of caps.
LP Gas
Set Up
Fig
7
Natural
Gas Set
Up
Fig
6
LP Gas
Set Up
Fig
8
Natural Gas
Set Up
Fig
5
Dust Protector
&219(57,1*
S
85)$&(%851(56
Photo B
Photo C
6#
Using a 3/16” nut driver
turn the burner mounting screws counter
clockwise to remove
as shown
&
photo B
'#
2#
The burner can then be lifted away from the cooktop
providing access to the burner
orifice as seen in photo C. Use a 7mm nut driver to remove
the orifice from the orifice
holder.
#
With the orifice removed
the size stamp is visible. Using the size stamp on the N
)
orifice
determine the correct LP orifice from the chart
below or from the instructions
provided in the LP conversion kit.
9# 6$ 1 $ $ "
!#
7! ! $ $ #
The chart at right can be used as a guide to identify the proper orifices
for the various burner sizes and styles that are currently used on the
300 and 500 series ranges. Future models may change
so
5 $
to the parts list or LP conversion kit for the specific model being serviced.
BTU
Rating/Style
5000
9500
9500/Oval 12000
14000
16000
Natural
Gas
Orifice
1.07
1.46
1.54
1.67
1.87
1.98
LP
Gas
Orifice
.66
.93
.89
1.02
1.09
1.18
LP
Orifice
Marking
Color
Pink
White
None Yellow
Brown
Silver
BTU
Rating
after
LP
Conversion
5000
9500
8000
12000
14000
16000