16
en | Installation
Loudspeaker line isolator system
2021.07.28 | V1.00 |
Installation manual
Bosch Security Systems B.V.
i
Notice!
If any short circuit is present on the speaker cable, LDB will immediately detect and isolate
the shorted connector and SHORT indication will appear on LDB front panel. If the speaker
cable connects to ground causing earth leakage, LDB will detect the earth leakage and EARTH
fault indication will appear on LDB front panel. See
PRA-LID (LDB) Indicators, buttons and
5.
If system includes multiple loops (multiple LDBs), there is a number of ways you can
interconnect Loudspeaker line isolator to the Public Address / Voice Alarm system.
6.
If you are planning to proceed with installation of FIM modules on the loop, leave the
SECONDARY
output of LDB disconnected.
7.
When loop is closed, and all FIMs on the loop are working properly, connect the incoming
loop cable to
SECONDARY
output of LDB. Loop is now fully secured.
Multiple LDBs can share common fault contact or individual fault control contacts of the main
system. Fault contact sharing allows you to reduce number of control inputs needed for fault
reports. Detailed information about the location and type of fault is always available on LDBs
front panels, as well as via Sniffer PC application.
Multiple LDBs can also share common power amplifier or have individual power amplifiers
from the main system. Amplifier sharing allows you to create multiple loops within one zone,
each with individual surveillance.
Refer to
–
PRA-LID (LDB) Indicators, buttons and connections, page 9
4.6
Installing PRA-LIM (FIM) on a loudspeaker line
Before you start connecting FIMs on the loop, make sure that LDB is connected to the rail and
powered. See
Installing order PRA-LID (LDB), page 15.
1.
For most efficient installation make sure that LDB is in
SERVICE
MODE
(blue
MODE
indicator blinking fast).
–
To put LDB into
SERVICE
MODE
press SERVICE button for 10 seconds or use Sniffer
PC application.
2.
During
SERVICE MODE
LDB will show
OPEN
fault indication as long as the loop is not
completely closed.
–
This is the correct indication, since the loop should be closed only at the final stage
of installation, to make sure that the entire course of the loop is complete.
i
Notice!
When the loudspeaker line isolator system is in SERVICE MODE, audio signal from power
amplifier is not transmitted to the loop.
3.
Double check if the loudspeaker line cable is connected to the
PRIMARY
loop output of
LDB and the
SECONDARY
loop output of LDB is not connected.
4.
LDB should indicate only
OPEN
fault. If
SHORT
fault is detected, fix it before FIM
installation.
5.
Check if
EOL
switch (
6
) on the FIM is in
OFF
position.
i
Notice!
EOL switch (6) should be in ON position only with EOL resistor connected to the termination
of T‑Branch line. Short circuits on T‑Branch are detected and isolated regardless the EOL
monitoring switch.