•  Hooded louver outside air intake with bird 

screen

•  Wall mounted, variable position motor controller

SpeCIfICATIonS

Available Sizes: 4", 5", and 6" round
Damper motor electrical rating: 24 VAC, 2.6 VA 
operating, 0.7 VA holding
Damper motor electrical Connections:
 Input:
 24 VAC, common, G (blower call from air 

handler), VP from the wall controller

 output: 5 VDC to wall controller
Duct material: 30 gage galvanized steel
Damper material: 28 gage galvanized steel
Damper motor Control: Wall mount potentiometer 
for damper opening allowing a certain percentage 
of air (0-100%)
hooded Air Intake louver: 4", 5", and 6" duct 
connection attached to an air intake hood to be 
mounted on exterior wall

ApplICATIon

The Bosch fresh outside air damper system 
introduces outside air for ventilation, providing 
healthier indoor air quality and for exhaust make up 
air. A typical installation is demonstrated in Figure 1.
Although there are many variations of installations 
depending on physical constraints and routing of 
the air duct, Figure 1 shows in general how to 

proDuCT InformATIon

The Bosch fresh outside air damper system allows 
fresh air to be introduced into the home for natural, 
healthy ventilation. As the building codes of 
residences are getting more restrictive on air 
leakage for energy effi ciency improvements, fresh 
air can only enter the house as doors and windows 
are opened. This typically lends to overused, 
re-circulated stale air. Depending on the amount of 
air that is being exhausted through the bathroom 
fans, kitchen hoods, and local code requirements; 
outdoor air may be required as make-up air for your 
home. Bringing in outside air improves the overall 
indoor air quality for you and your family.

feATureS

•  Fully modulating (0-90°) damper position
•  Power open / Power close 24VAC modulating 

damper motor

•  Rated up to 1” w.c. with an 80 in-oz (5 in-lbs) 

torque damper motor

•  Constructed of 30 gage, galvanized steel
•  Two 28 gage, galvanized steel blades with 

rubber gasket sandwiched between blades

•  Crimped and un-crimped ends for easy 

connection to round duct

•  Fully opens or closes in 2.75 seconds
•  LED indication lights of damper position; Green 

indicates fully open, Red indicates fully closed

product Information 

IAQ Series  3

figure #1

Summary of Contents for FADB-04007-6--A

Page 1: ...Installation and Maintenance Manual IAQ Series FADB 04007 6 A FADB 05011 6 A FADB 06015 6 A 6720220345 Revised 07 12 Fresh Air Damper System ...

Page 2: ...le of Contents Product Information 3 Features 3 Specifications 3 Application 3 Installation Considerations 4 Installation 5 Wiring 5 Controlling the Outside Air Damper 6 Homeowner Considerations 6 Contact your local Bosch Dealer or Installing Contractor for product support 7 Product Limited Warranty 8 ...

Page 3: ...nd routing of the air duct Figure 1 shows in general how to proDuCT InformATIon The Bosch fresh outside air damper system allows fresh air to be introduced into the home for natural healthy ventilation As the building codes of residences are getting more restrictive on air leakage for energy efficiency improvements fresh air can only enter the house as doors and windows are opened This typically l...

Page 4: ... and Bosch recommends that a qualified HVAC contractor or a professional engineer size the duct and verify that the additional pressure drop will not adversely affect the air flow delivered by the HVAC fan motor 3 The routing of the spiral duct must be considered Length of duct as well as any fittings will provide excess pressure drop to the HVAC duct system this may adversely affect the fan motor o...

Page 5: ... hole through the exterior wall for the intake hood and duct 4 Securely fasten the hooded louver intake to the exterior wall Installation IAQ Series 5 5 Route the required sized duct as determined by the HVAC contractor or professional engineer from the louver intake duct connection to the damper 6 Route the required sized duct as determined by the HVAC contractor or professional engineer from the...

Page 6: ...Simply turn the knob to the appropriate amount of outside air If the percentage of air is adjusted for a short time duration due to activities or possibly by smoke being created by burning food ensure that the controller is returned to the initial setting once the situation is back to normal Leaving the damper wide open when it is not needed can lead to IAQ issues by introducing humid air or dry a...

Page 7: ...ocation 3 Routinely check the bird screen underneath the hooded louver intake to ensure that there is not debris blocking the air flow Contact your local Bosch Dealer or Installing Contractor for product support Field Technical Support 954 776 5471 Monday Friday 8 am 5 pm EST Bosch 601 N W 65th Ct Ft Lauderdale FL 33309 www bosch climate us Contact your Local Bosch Dealer IAQ Series 7 Table 1 Repl...

Page 8: ...sts for removal reinstallation repair and replacement of the defective component or part 7 Electricity or fuel costs or any increases or unrealized savings in same for any reason whatsoever 8 Damage caused by excessive temperatures or pressures fuel or gas explosion electrochemical reaction water and air impurities electrical failures use during construction flooding or acts of God 9 Any damage or...

Page 9: ...PERSONS OR PROPERTY OR DAMAGES FOR LOSS OF USE LOST PROFITS INCONVENIENCE OR LOSS OF TIME Caution Note that any repaired or replaced product will be warranted for only the unexpired tem of the original warranty Caution Some states do not allow the exclusion of limitation of damages or limitations on how long an implied warranty lasts so the above limitations and exclusions may not apply to you WAr...

Page 10: ...Subject to change without prior notice Revised 07 12 6 720 220 345 10 IAQ Series Notes ...

Page 11: ...6 720 220 345 Revised 07 12 Subject to change without prior notice Notes IAQ Series 11 ...

Page 12: ...601 N W 65th Court Ft Lauderdale FL 33309 Phone 954 776 5471 Fax 954 776 5529 www bosch climate us ...

Reviews: