background image

 

6 720 220 345

Revised 07-12                                Subject to change without prior notice

product limited Warranty 

IAQ Series  9

accessory or component not authorized and 
approved by FHP. See the Installation and 
Maintenance Manual for installation and 
maintenance information.

4.   Failure or malfunction due to misapplication or 

faulty building design or construction, including 
inadequate refrigerant levels, condensate drain, 
duct work design or installation.

5.   Product on which payment to FHP is or has been 

in default.

6.   Work performed without prior authorization or 

approval and without authorization/requisition 
number and without proper documentation 
verifying compliance with above terms.

lImITeD WArrAnTy

OTHER THAN THE OBLIGATIONS OF FHP 
EXPRESSLY SET FORTH HERIN, fhp DISClAImS 
All WArrAnTIeS, eXpreSS or ImplIeD, 
InCluDIng buT noT lImITeD To Any ImplIeD 
WArrAnTIeS of merChAnTAbIlITy or fITneSS 
for A pArTICulAr purpoSe.
 FHP’S SOLE 
OBLIGATION WITH RESPECT TO THE PRODUCT 
AND purChASer’S eXCluSIVe remeDIeS Are 
SeT forTh In The foregoIng lImITeD 
WArrAnTy. fhp ShAll noT be lIAble for Any 
InDIreCT, punITIVe, InCIDenTAl, SpeCIAl, 
ConSeQuenTIAl or SImIlAr DAmAgeS 
INCLUDING, WITHOUT LIMIITATION, INJURY OR 
DAMAGE TO PERSONS OR PROPERTY OR 
DAMAGES FOR LOSS OF USE, LOST PROFITS, 
INCONVENIENCE OR LOSS OF TIME.

Caution

Note that any repaired or replaced product will 
be warranted for only the unexpired tem of the 
original warranty.

Caution

Some states do not allow the exclusion of 
limitation of damages, or limitations on how 
long an implied warranty lasts, so the above 
limitations and exclusions may not apply to you.

WArrAnTy ClAImS proCeSS

If you have a warranty claim you should notify the 
contractor who installed your Product and ask that 
the contractor notify FHP Manufacturing Company, 
601 N.W. 65th Court, Ft. Lauderdale, FL 33309. To 
process your claim, you will need a copy of your 
original invoice or other proof of purchase, the 
product serial number and documentation showing 
the original installation date and location. The 
alleged defective components or parts must be 
returned to FHP in accordance with FHP procedure 
then in force for handling goods returned for the 
purpose of inspection to determine cause of failure 
(contact FHP if you have questions regarding the 
return process). If FHP determines that the returned 
components and/or parts are defective and that this 
warranty applies, FHP will furnish the repaired or 
replacement components and/or parts to the 
contractor who installed your Product.
This Warranty applies to FHP products installed in 
the Continental United States and Canada only

Summary of Contents for FADB-04007-6--A

Page 1: ...Installation and Maintenance Manual IAQ Series FADB 04007 6 A FADB 05011 6 A FADB 06015 6 A 6720220345 Revised 07 12 Fresh Air Damper System ...

Page 2: ...le of Contents Product Information 3 Features 3 Specifications 3 Application 3 Installation Considerations 4 Installation 5 Wiring 5 Controlling the Outside Air Damper 6 Homeowner Considerations 6 Contact your local Bosch Dealer or Installing Contractor for product support 7 Product Limited Warranty 8 ...

Page 3: ...nd routing of the air duct Figure 1 shows in general how to proDuCT InformATIon The Bosch fresh outside air damper system allows fresh air to be introduced into the home for natural healthy ventilation As the building codes of residences are getting more restrictive on air leakage for energy efficiency improvements fresh air can only enter the house as doors and windows are opened This typically l...

Page 4: ... and Bosch recommends that a qualified HVAC contractor or a professional engineer size the duct and verify that the additional pressure drop will not adversely affect the air flow delivered by the HVAC fan motor 3 The routing of the spiral duct must be considered Length of duct as well as any fittings will provide excess pressure drop to the HVAC duct system this may adversely affect the fan motor o...

Page 5: ... hole through the exterior wall for the intake hood and duct 4 Securely fasten the hooded louver intake to the exterior wall Installation IAQ Series 5 5 Route the required sized duct as determined by the HVAC contractor or professional engineer from the louver intake duct connection to the damper 6 Route the required sized duct as determined by the HVAC contractor or professional engineer from the...

Page 6: ...Simply turn the knob to the appropriate amount of outside air If the percentage of air is adjusted for a short time duration due to activities or possibly by smoke being created by burning food ensure that the controller is returned to the initial setting once the situation is back to normal Leaving the damper wide open when it is not needed can lead to IAQ issues by introducing humid air or dry a...

Page 7: ...ocation 3 Routinely check the bird screen underneath the hooded louver intake to ensure that there is not debris blocking the air flow Contact your local Bosch Dealer or Installing Contractor for product support Field Technical Support 954 776 5471 Monday Friday 8 am 5 pm EST Bosch 601 N W 65th Ct Ft Lauderdale FL 33309 www bosch climate us Contact your Local Bosch Dealer IAQ Series 7 Table 1 Repl...

Page 8: ...sts for removal reinstallation repair and replacement of the defective component or part 7 Electricity or fuel costs or any increases or unrealized savings in same for any reason whatsoever 8 Damage caused by excessive temperatures or pressures fuel or gas explosion electrochemical reaction water and air impurities electrical failures use during construction flooding or acts of God 9 Any damage or...

Page 9: ...PERSONS OR PROPERTY OR DAMAGES FOR LOSS OF USE LOST PROFITS INCONVENIENCE OR LOSS OF TIME Caution Note that any repaired or replaced product will be warranted for only the unexpired tem of the original warranty Caution Some states do not allow the exclusion of limitation of damages or limitations on how long an implied warranty lasts so the above limitations and exclusions may not apply to you WAr...