Ordering information

Fireray3000

End-to-End Linear Smoke Detector for ranges between
5 m - 120 m (max. 100m according to DIN VDE 0833-2)

Order number 

Fireray3000

Accessories
Fireray3000-HD

Additional detector head

Order number 

Fireray3000-HD

 

4 | Fireray3000

Represented by:

Americas:

Europe, Middle East, Africa:

Asia-Pacific:

China:

America Latina:

Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us

Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com

Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia

Bosch (Shanghai) Security Systems Ltd.
201 Building, No. 333 Fuquan Road
North IBP
Changning District, Shanghai
200335 China
Phone +86 21 22181111
Fax: +86 21 22182398
www.boschsecurity.com.cn

Robert Bosch Ltda Security Systems Division
Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil
Phone: +55 19 2103 2860
Fax: +55 19 2103 2862
latam.boschsecurity@bosch.com
www.boschsecurity.com

© Bosch Security Systems 2013 | Data subject to change without notice
12949575563 | en, V1, 04. Dec 2013

Summary of Contents for Fireray3000

Page 1: ...rding to DIN VDE 0833 2 the core diameter of the light beam is 3 m The core diameter is the area of the conical IR beam in which orderly operation of the system is possible If smoke interrupts the beam the signal in the receiver is attenuated depending on the thickness of the smoke If an attenuation according to the set threshold lasts longer than 5 s an alarm is triggered The alarm threshold can ...

Page 2: ...moke to the ceiling The detector must therefore be mounted below an expected heat accumulation This can mean that the benchmark values for DL specified in the table must be exceeded 30 60 cm C B A D installation_for_smoke_plume Pos Description A Ceiling B Mushroom cloud C Heat accumulation D IR beam Since the smoke from a fire does not simply rise straight up but rather spreads like a mushroom clo...

Page 3: ... on use and environmental conditions e g quick fire and spread of smoke Depending on the roof construction flat tilted or gable the detectors and receiver must be arranged according to the roof pitch α and the room height RH so that the light beam runs along the roof in a distance DL see table Parts included Qty Components 1 Control Unit Fireray3000 Linear Smoke Detector 1 Infrared transmitter 1 I...

Page 4: ...en The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Robert Bosch SEA Pte Ltd Security Systems 11 Bishan Street 21 Singapore 573943 Phone 65 6571 2808 Fax 65 6571 2699 apr securitysystems bosch com www boschsecurity asia Bosch Shanghai Security Systems Ltd 201 Building No 333 Fuquan Road North IBP Changning District Shanghai 200335 China P...

Reviews: