Operation
–
Off
: the built-in plate heat exchanger in the
heating appliance is not kept constantly
hot (eco mode); as a result energy is saved.
In eco mode, the hot tap has to be run for
a short while before the water becomes
hot.
•
If the DHW cylinder and FR 100 are directly
connected to the heating appliance, the DHW
program switches between the following
operating modes:
–
On
: Cylinder heating enabled (temperature
in accordance with setting on heating
appliance).
–
Off
: Cylinder heating blocked.
•
With appliances connected to a DHW cylinder
and FR 110, the DHW program specifies the
required water temperature (set
temperature).
–
If the temperature measured in the DHW
cylinder is below the set temperature, the
cylinder is reheated.
–
Once the set temperature is reached (or
exceeded), cylinder reheating is stopped.
DHW circulation program
The DHW circulation program specifies when a
connected DHW circulation pump for domestic
hot water runs.
5.2 Setting programs
5.2.1 Display views and menu navigation
The user interface of the FR 100 / FR 110 room
temperature-dependent heating controller is
implemented as a so-called "menu". Within that
menu, the various functions are arranged in a
hierarchical structure. For greater clarity, the
menu is subdivided into three sections (
MAIN
MENU
,
INFO
,
INSTALLER SETTINGS
). Each
section can be accessed by its own button. The
entire menu structure is shown in tabular form in
chapters 6.1, 7 and 8.1.
To navigate through the menu:
•
Press
to
open
MAIN MENU
. From any
point within the
MAIN MENU
, press
to
go back to the standard display.
•
Press
to open the
INFO
menu. From any
point within the
INFO
menu, press
to go
back to the standard display.
•
Hold down
for at least 3 seconds to open
the
INSTALLER SETTINGS
menu. From any
point within the
INSTALLER SETTINGS
menu,
press
to go back to the standard display.
•
The selected menu point/parameter is
displayed in
colours, i.e. white on
black.
•
Arrows in the left margin indicate that there is
more information than can be shown on the
display at once. It can be viewed with
.
•
opens the submenu associated with the
selected menu point/parameter or activates
editing mode for the parameter (the
parameter setting starts flashing).
If the DHW program changes from a
higher to a lower temperature, the
water in the cylinder will not
immediately cool to the lower
temperature, i.e. water at a higher
temperature will continue to be
available for some time. However,
the cylinder will not be reheated
until the temperature falls below
the new set temperature.