6 720 645 347 (2010/09)
Menu settings INSTALLER SETTINGS (for contractors only)
|
55
8.1.1 INSTALLER SETTINGS: System configuration
8.1.2 INSTALLER SETTINGS: Heating parameters
8.1.3 INSTALLER SETTINGS: Solar system config
Menu structure
System configuration
Factory
setting
Setting range
Personal
setting
Description
from page
Connection type
–
BUS | 1-2-4 (only with FR 100)
58
Start automatic system
configuration
No
No | Yes
Domestic hot water
configuration
1)
With FR 100:
Combi boiler
No | Combi boiler | Cyl conn to
boiler
Cyl conn to
boiler
No | Combi boiler | Cyl conn to
boiler | Cyl on IPM ident. 3 ... 10
DHW circulation pump
2)
No
No | Present
CH system configuration
Unmixed
without IPM
Unmixed without IPM | Unmixed
with IPM | Mixed
Identification CH circuit
1
1 ... 10 (only FR 100 with BUS
connection)
ISM 1
No
No | Present
ISM 2
No
No | Present
1) Only FR 110 or FR 100 with code 1
2) Only with FR 110
Menu structure
Heating parameters
Factory
setting
Setting range
Personal
setting
Description
from page
Calibrate room temperature
sensor
0.0 K
– 3.0 K ... 3.0 K
K
59
Adjustment factor I
40 %
0 % ... 100 %
%
Amplification factor V
80 %
40 % ... 100 %
%
Heat-up optimisation
No
No | Yes
Maximum CH flow temperature 75 °C
30 °C ... 85 °C
°C
Mixer running time
140 s
10 s ... 600 s
s
Menu structure
Solar system config
Factory
setting
Setting range
Personal
setting
Description
from page
Solar sys option E Thermal
disinfection
No
No | Yes
60