Menu settings INSTALLER SETTINGS (for contractors only)
8.1.4 INSTALLER SETTINGS: Solar sys parameters
8.1.5 INSTALLER SETTINGS: Fault history
8.1.6 INSTALLER SETTINGS: Cust service address
Menu structure
Solar sys parameters
Factory
setting
Setting range
Personal
setting
Description
from page
1. Standard system
–
–
–
61
SP: ON temperature
difference
8 K
3 K ... 20 K
(not lower than “SP: OFF
temperature difference” +1 K)
K
SP: OFF temperature
difference
4 K
2 K ... 19 K
(not higher than “SP: ON
temperature difference” – 1 K)
K
T2: Max. solar cylinder
temperature
60 °C
15 °C ... 90 °C
°C
Maximum collector
temperature
120 °C
100 °C ... 140 °C
°C
SP: Collector grp 1 pump
mode
Auto
Auto | Manual On | Manual Off
PE: Therm disinfect pump
mode
Auto
Auto | Manual On | Manual Off
60
Solar optimisation
62
Collector group 1 area
0.0 m
2
0.0 m
2
... 150.0 m
2
m
2
Collector group 1 type
Flat plate
collector
Flat plate collector | Vac tube
collector
Climate zone
90
0 ... 255
Optimizing influence DHW
0 K
0 K (= function off) ... 20 K
K
Run solar system
No
No | Yes
61
Menu structure
Fault history
Factory
setting
Setting range
Personal
setting
Description
from page
01.01.2010
16:11
Fault EA
(example for last fault)
– –
–
64
25.09.2010
18:45
FAULT 44 - IPM IDENT. 10
(up to a maximum of 19
previous faults)
– –
–
Menu structure
Cust service address
Example
Setting range
Personal
setting
Description
from page
Telephone number
012345 6789
Max. 20 characters
64
Name
Heating
contractor
Max. 20 characters