Menu settings INSTALLER SETTINGS (for contractors only)
8.2 Configuring the heating system
Contractor level: System configuration
Use this menu if you want to configure the system
automatically or manually, e.g. when
commissioning or making changes to the system.
•
Connection type
for the setting of the type of
connection with the Heatronic 3 (only FR 100).
•
Start automatic system configuration
for
starting automatic configuration.
•
Domestic hot water configuration
for the
manual configuration of the DHW system (only
for FR 100 with code 1 or FR 110).
•
CH system configuration
for the
configuration of the assigned heating circuit.
•
DHW circulation pump
: This menu point is
only active if a DHW circulation pump has
been installed in the DHW system (only for
FR 110).
•
Identification CH circuit
for the selection of
the associated heating circuit (1 ... 10 – only
FR 100)
When commissioning a heating system, proceed
as follows:
B
Code all BUS subscribers in accordance with
their function (e.g. IPM 1 for heating circuit 1
etc.).
B
Start automatic configuration.
B
Check the other menu points under
System
configuration
and, if necessary, adjust
manually to suit the current system.
For menu structure and setting ranges
Æ
page 55.
An example system is shown in
chapter 2.5 on page 12. Other
examples can be found in the
instructions for the IPM or the
technical guides.
The heating system's solar thermal
system must be configured
manually (
Æ
chapter 8.4,
page 60). Automatic configuration
of the heating system does not
configure the solar thermal
system.