Applications Manual Bosch Greenstar
| 57
Bosch Thermotechnology Corp.
Data subject to change
System #26
BUS
TT
out sen
LWCO
DHW sen
1
2
3
4
5
6
reset
eco
1
2
3
4
5
6
max
1
2
3
4
e
6
max
DHW thermostat
min
e
max
Typical DHW temperatures
approx. 104 °F (40 °C)
approx. 122 °F (50 °C)
approx. 140 °F (60 °C)
Boiler
Heating
Dial
1
2
3
Typical supply
temperatures
approx. 95 °F (35 °C)
approx. 109 °F (43 °C)
approx. 122 °F (50 °C)
4
5
6
approx. 140 °F (60 °C)
approx. 153 °F (67 °C)
approx. 167 °F (75 °C)
max
Approx. 194 °F (90°C)
Application
Frost protection
Radiant floor heating
Panel radiator system
Cast Iron radiator system
Baseboard & convector system
Neutral
120 V Line
Ground
Low Voltage Wiring
Line Voltage Wiring
Heatronic Settings:
Low Voltage
Ź
Wire Bosch Control to Terminal # 1 on back of
Greenstar FS Boiler
Wiring:
Line Voltage
Ź
Wire Main power supply (120 v) to White molex
L
N
black
ch pump
for unmixed heating
(Not Used)
L
N
white
mains
120v/60 hz
Note: For Low Water Cutoff Wiring see
Appendix E of this manual
Bosch
Control
Summary of Contents for FS 100
Page 2: ...2 Bosch Greenstar Applications Manual Bosch Thermotechnology Corp Data subject to change ...
Page 73: ...Applications Manual Bosch Greenstar 73 Bosch Thermotechnology Corp Data subject to change ...
Page 74: ...74 Bosch Greenstar Applications Manual Bosch Thermotechnology Corp Data subject to change ...
Page 75: ...Applications Manual Bosch Greenstar 75 Bosch Thermotechnology Corp Data subject to change ...