22
| English
Cleaning the pre-filter
– Open the catches
(9)
and remove the top part of the va-
cuum cleaner
(10)
(see figure
C
).
– Remove the pre-filter
(22)
from the container
(7)
.
– Shake out the pre-filter
(22)
over a suitable waste bin.
– Insert the pre-filter
(22)
in the container
(7)
, making sure
that the arrows are pointing towards the hose connection
piece
(3)
.
– Put the top part of the vacuum cleaner
(10)
on and close
the catches
(9)
.
Cleaning the main filter
– Open the catches
(9)
and remove the top part of the va-
cuum cleaner
(10)
(see figure
C
).
– Turn the filter holder
(28)
as far as possible in the direc-
tion of rotation
and take the filter holder, together with
the main filter
(20)
, out of the top part of the vacuum
cleaner
(10)
.
– Brush the folds of the main filter
(20)
with a soft brush.
or
Replace the main filter
(20)
if damaged.
– Place the filter holder
(28)
, together with the main filter
(20)
, over the filter basket
(29)
and turn the filter holder
(28)
as far as possible in the direction of rotation
.
– Put the top part of the vacuum cleaner
(10)
on and close
the catches
(9)
.
Cleaning the wet filter
To prevent mould growth after wet vacuuming:
– Open the catches
(9)
and remove the top part of the va-
cuum cleaner
(10)
(see figure
C
).
– Leave the top part of the vacuum cleaner
(10)
to dry thor-
oughly.
– Pull the wet filter
(21)
out of the filter basket
(29)
.
– Wash the wet filter
(21)
under running water and then
leave it to dry thoroughly.
– Place the wet filter
(21)
completely over the filter basket
(29)
.
– Put the top part of the vacuum cleaner
(10)
on and close
the catches
(9)
.
Storage and Transport (see figure J1–J2)
– Wrap the power cable around the carrying handle
(12)
.
– Place the suction tubes
(26)
in the holders
(14)
.
– Place the vacuum hose
(15)
in the holder
(11)
around
the top part of the vacuum cleaner.
– Carry the vacuum cleaner by the carrying handle
(12)
or
pull the vacuum cleaner along behind you on even sur-
faces using the pull strap
(4)
.
– Store the vacuum cleaner in a dry room and secure it so
that it cannot be used by unauthorised persons.
– Put the castor brake
(5)
down to hold the castors
(6)
in
place.
Rectifying faults
u
If a fault (e.g. a filter damage) occurs, the vacuum
cleaner must be switched off immediately. The fault
must be repaired before resuming operation.
Problem
Corrective measures
The suction turbine will not switch on. – Check the mains cable, mains plug, fuse and socket.
The mode selector switch
(1)
is set to "automatic start/stop".
– Set the mode selector switch
(1)
to the "extraction" symbol or switch on the
power tool plugged into the electric socket
(2)
.
The suction turbine will not switch
back on after the container has been
emptied.
– Switch the dust extractor off and wait five seconds before switching it back on.
The suction power is decreasing.
– Empty the container
(7)
.
– Remove any blockages from the extraction nozzle, suction tube
(26)
, vacuum
hose
(15)
or main filter
(20)
.
– Change the plastic bag
(19)
or dust bag.
– Make sure the filter holder
(28)
is engaged correctly.
– Place the top part of the dust extractor
(10)
on correctly and close the catches
(9)
.
– Change the pre-filter
(22)
, main filter
(20)
or wet filter
(21)
.
Dust is escaping during extraction
– Check that the main filter
(20)
has been fitted correctly.
– Change the main filter
(20)
.
Automatic switch-off (wet extraction)
is not working.
Automatic switch-off will not work in the presence of non-conductive liquids or foam-
ing.
1 609 92A 4CP | (09.11.2018)
Bosch Power Tools