Remove the batteries from the measuring tool when 
not using it for extended periods. 

When storing for ex-

tended periods, the batteries can corrode and self-dis-
charge.

Working with the Rotating Mount RM 1 
(see figures A1 – A2)

You can use the rotating mount 

13

 to rotate the measuring 

tool 360° around a central, always visible plumb point. This 
enables you to set up the laser lines precisely, without having 
to change the position of the measuring tool.

– Place the measuring tool with the guide groove 

8

 on the 

guide rail 

14

 of the rotating mount 

13

 and slide the meas-

uring tool to the stop onto the platform.
To disconnect, pull the measuring tool in the opposite di-
rection from the rotating mount.

Positioning possibilities of the rotating mount:
– standing on a flat surface,
– screwed to a vertical surface,
– on metallic surfaces using the magnets 

16

,

– on metallic ceiling strips using the ceiling clip 

17

.

Operation

Initial Operation

Protect the measuring tool against moisture and direct 
sun light.

Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. 

As an example, do 

not leave it in vehicles for a long time. In case of large vari-
ations in temperature, allow the measuring tool to adjust to 
the ambient temperature before putting it into operation. 
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool can be impaired.

Avoid heavy impact to or falling down of the measuring 
tool. 

Damage to the measuring tool can impair its accura-

cy. After heavy impact or shock, compare the laser lines or 
plumb beams with a known horizontal or vertical reference 
line or with already checked plumb points.

Switch the measuring tool off during transport. 

When 

switching off, the levelling unit, which can be damaged in 
case of intense movement, is locked.

Switching On and Off

To save energy, only switch the measuring tool on when you 
are using it.

Do not leave the switched-on measuring tool unattend-
ed and switch the measuring tool off after use. 

Other 

persons could be blinded by the laser beam.

– To 

switch on

 the measuring tool, slide the On/Off switch 

2

 

to position 

 (for working without automatic level-

ling) or to position 

 (for working with automatic 

levelling).
As soon as it is switched on, the measuring tool emits laser 
lines from the exit openings 

1

.

– To 

switch off

 the measuring tool, slide the On/Off switch 

2

 

to position 

.

The pendulum unit is locked when the tool is switched off.

When exceeding the maximum permitted operating tempera-
ture of 50 °C, the measuring tool switches off to protect the 
laser diode. After cooling down, the measuring tool is ready 
for operation and can be switched on again.

Automatic Shut-off

When no button on the measuring tool is pressed for approx. 
120 minutes, the measuring tool automatically switches off 
to save the batteries.

– To  switch  the  measuring  tool  back on after automatic shut-

off, you can either slide the On/Off switch 

2

 to position 

 first and then switch the measuring tool back on, or 

press either button 

5

 or button 

6

.

Deactivating the Automatic Shut-off:
– To deactivate automatic shut-off, hold down button 

6

 for at 

least 3 s with the measuring tool switched on. If automatic 
shut-off is deactivated, the laser lines will flash briefly as 
confirmation.

Note: 

If the operating temperature exceeds 45°C, automatic 

shut-off can no longer be deactivated.

Activating the Automatic Shut-off:
– To activate the automatic shut-off, switch the measuring 

tool off and then on again.

Setting the operating mode (see figures B1–F1)

The measuring tool has several operating modes between 
which you can switch at any time:

Cross-line and point operation:

 The measuring tool gen-

erates a horizontal and a vertical laser line facing front-
ward, a vertical laser point facing upward and a vertical la-
ser point facing downward.
The laser lines cross at a 90° angle.

Point operation:

 The measuring tool generates a vertical 

laser point facing upward and a vertical laser point facing 
downward.

Horizontal line operation:

 The measuring tool generates 

a horizontal laser line facing frontward.

Vertical line operation:

 The measuring tool generates a 

vertical laser line facing frontward.
If the measuring tool is positioned in the room, the vertical 
laser line is displayed on the ceiling beyond the upper laser 
point.
If the measuring tool is positioned directly against a wall, 
the vertical laser line generates an almost completely all-
round laser line (360° line).

All modes except for point operation can be selected both 
with and without automatic levelling.

OBJ_BUCH-2637-002.book  Page 18  Wednesday, June 22, 2016  4:13 PM

Summary of Contents for GCL 2-15

Page 1: ...rough quali fied specialists using original spare parts This ensures that the safety of the measuring tool is maintained Do not allow children to use the laser measuring tool without supervision They could unintentionally blind other persons or themselves Donotoperatethemeasuringtoolinexplosiveenviron ments such as in the presence of flammable liquids gases or dusts Sparks can be created in the me...

Page 2: ...er points 0 3 mm m 0 7 mm m 0 3 mm m 0 7 mm m Self levelling range typically 4 4 Levelling duration typically 4 s 4 s Operating temperature 10 C 50 C 10 C 50 C Storage temperature 20 C 70 C 20 C 70 C Relative air humidity max 90 90 Laser class 2 2 Laser type Laser point Laser line 630 650 nm 1 mW 630 650 nm 1 mW 500 540 nm 1 mW 630 650 nm 1 mW Colour of laser beam red green C6 1 1 Divergence Laser...

Page 3: ...o position for working with automatic levelling As soon as it is switched on themeasuringtoolemitslaser lines from the exit openings 1 Toswitchoffthemeasuringtool slidetheOn Offswitch2 to position The pendulum unit is locked when the tool is switched off When exceeding the maximum permitted operating tempera ture of 50 C the measuring tool switches off to protect the laser diode After cooling down...

Page 4: ... levelling Figure On Offswitch2inposition green B1 Cross line operation Press button for laser line operating mode 6 once green C1 Press button for laser line operating mode 6 twice green D1 Press button for laser line operating mode 6 three times green E1 Press button for laser line operating mode 6 four times green B1 Cross line operation Point operation can be activated or deactivated regardles...

Page 5: ...uences on Accuracy The ambient temperature has the greatest influence Espe cially temperature differences occurring from the ground up ward can divert the laser beam In addition to external influences device specific influences e g falls or heavy impacts can also lead to deviations For this reason check the levelling accuracy each time before be ginning work First checkboththeheightaswellastheleve...

Page 6: ...ght of the measuring tool using a tripod or by underlaying if required in such a manner that the centre of the laser line is projected exactly against the previously marked point II on wall B Mark the centre of the laser line as point III vertically above or below point I on the wall A The difference d of both marked points I and III on wall A indicates the actual deviation of the measuring tool f...

Page 7: ...viation of the measuring tool to the plumb line The maximum permitted deviation dmax can be calculated as follows dmax double the distance between floor and ceiling x 0 7 mm m Example If the distance from the floor to the ceiling is 5 m the maximum deviation is dmax 2 x 5 m x 0 7 mm m 7 mm The marks must there fore be maximum 7 mm apart Working Advice For marking always use only the centre of the ...

Page 8: ...ater Park North Orbital Road Denham Uxbridge UB 9 5HJ At www bosch pt co uk you can order spare parts or arrange the collection of a product in need of servicing or repair Tel Service 0344 7360109 E Mail boschservicecentre bosch com Ireland Origo Ltd Unit 23 Magna Drive Magna Business Park City West Dublin 24 Tel Service 01 4666700 Fax 01 4666888 Australia New Zealand and Pacific Islands Robert Bo...

Reviews: