English |
17
Bosch Power Tools
F 016 L81 183 | (28.4.16)
Alarm
Troubleshooting
Charging power
Indication
Meaning
Measure
Critical state of charge
Remove load from the product and recharge im-
mediately
Critical temperature
Product will not work until temperature is within
limits. Let the product cool down.
All other critical situations on the product
Switch off the product for 1–2 hours and re-
charge. If error code persist, contact your deal-
er.
Temperature is too low
Let the product warm up
No display show:
– Too hot
– Too cold
– Damaged
i.e. turned off (6 sec. after charge mode)
– Let the product cool down
– Let the product warm up
– Replace product
Problem
Possible Cause
Corrective Action
Product does not
charge
Faulty mains power cable or plug
Replace mains power cable or blown fuse (UK 13 A
adapter)
Wrong mains power cable
Use the specified power cable
Product power cable not properly plugged
Insert mains plug fully into the mains input socket
Residual Current Device (RCD) or Miniature Circuit
Breaker (MCB) – tripped off
Reset the RCD or MCB
Remove any extension cable used and charge the
product using the wall socket
Supply voltage outside range
Check that the supply voltage is within
220 – 240 V
Temperature too high or too low
Product will not charge until temperature is within
limits (refer to specification), let product cool
down or warm up
Full state of charge is reached
Disconnect from the mains and use/store product.
Continue in inverter or combined mode
Clip fell off
Input cable pulled at wrong angle
Refit the clip
E51
E54
Exxx
OBJ_BUCH-2703-003.book Page 17 Thursday, April 28, 2016 11:24 AM