English |
7
(23)
Inlay
A)
A)
Accessories shown or described are not included with the
product as standard. You can find the complete selection of
accessories in our accessories range.
Technical Data
Line laser
GLL 3-60 XG
Article number
3 601 K63 Z..
Working range (radius)
A)
– Standard
30 m
– in receiver mode
25 m
– with laser receiver
5–60 m
Levelling accuracy
B)C)D)
±0.3 mm/m
Self-levelling range
±3°
Levelling time
< 4 s
Operating temperature
–10 °C to +40 °C
Storage temperature
–20 °C to +70 °C
Max. altitude
2000 m
Relative air humidity max.
90 %
Pollution degree according to
IEC 61010-1
2
E)
Laser class
2
Laser type
500–540 nm, < 10 mW
C
6
10
Divergence
50 × 10 mrad (full angle)
Shortest pulse duration
1/10000 s
Compatible laser receiver
LR 7
Tripod mount
1/4", 5/8"
Batteries
4 × 1.5 V LR6 (AA)
Duration of operation with
3 laser planes
B)
4 h
Weight according to
EPTA-Procedure 01:2014
0.78 kg
Dimensions
(length × width × height)
149 × 84 × 142 mm
Protection rating
IP 54 (dust and splash-
proof)
A) The working range may be reduced by unfavourable environ-
mental conditions (e.g. direct sunlight).
B) At
20–25
°C
C) Applies to the four horizontal intersection points
D) The values stated presuppose normal to favourable environ-
mental conditions (e.g. no vibration, no fog, no smoke, no direct
sunlight). Extreme fluctuations in temperature can cause devi-
ations in accuracy.
E) Only non-conductive deposits occur, whereby occasional tem-
porary conductivity caused by condensation is expected.
The serial number
(13)
on the type plate is used to clearly identify
your measuring tool.
Assembly
Inserting/changing the batteries
It is recommended that you use alkaline manganese batter-
ies to operate the measuring tool.
To open the battery compartment cover
(11)
, press on the
locking mechanism
(10)
and remove the battery compart-
ment cover. Insert the batteries.
When inserting the batteries, ensure that the polarity is cor-
rect according to the illustration on the inside of the battery
compartment.
The battery indicator
(2)
always indicates the current bat-
tery status:
LED
Capacity
Green continuous light
100−75 %
Yellow continuous light
75−35 %
Red continuous light
35−10 %
No light
Batteries drained
If the batteries are running low, the laser lines will gradually
become dimmer.
Always replace all the batteries at the same time. Only use
batteries from the same manufacturer and which have the
same capacity.
u
Take the batteries out of the measuring tool when you
are not using it for a prolonged period of time.
The bat-
teries can corrode and self-discharge during prolonged
storage in the measuring tool.
Operation
Starting Operation
u
Protect the measuring tool from moisture and direct
sunlight.
u
Do not expose the measuring tool to any extreme tem-
peratures or fluctuations in temperature.
For example,
do not leave it in a car for extended periods of time. If it
has been subjected to significant fluctuations in temper-
ature, first allow the measuring tool to adjust to the ambi-
ent temperature and then always carry out an accuracy
check before continuing work (see "Accuracy Check of
the Measuring Tool", page 9).
The precision of the measuring tool may be compromised
if exposed to extreme temperatures or fluctuations in
temperature.
u
Avoid substantial knocks to the measuring tool and
avoid dropping it.
Always carry out an accuracy check
before continuing work if the measuring tool has been
subjected to severe external influences (see "Accuracy
Check of the Measuring Tool", page 9).
u
Switch the measuring tool off when transporting it.
The pendulum unit is locked when the tool is switched off,
as it can otherwise be damaged by big movements.
Bosch Power Tools
1 609 92A 5MK | (30.03.2020)