36
7.
Position the relevant burner cap (A) exactly on top of the cup
(B).
8.
Refit the pan supports.
Setting the minimum gas flow
1.
Switch on the gas burner.
2.
Turn the control knob for the gas burner towards the small
flame setting.
3.
Remove the control knob for the gas burner.
4.
Adjust the internal setting screw until a stable flame is
burning correctly.
Loosen the adjuster screw to increase the gas flow or tighten
it to decrease the gas flow.
Check that the flame does not go out when the gas flow is
quickly changed between maximum and minimum, and vice
versa.
The setting is correct when the height of the small flame is
approx. 3 to 4 mm.
5.
Refit the control knob for the gas burner.
General nozzle table
Nominal operating pressure
The nominal operating pressure of your appliance is:
■
for natural gas - NG (G20) 20 mbar / 2.0 kPa.
■
for liquefied gas - LPG (G30) 30 mbar / 3.0 kPa.
■
for liquefied gas - LPG (G31) 37 mbar / 3.7 kPa.
Your appliance must be operated at these pressure values. All
information on the rating plate refers to these pressure values.
The manufacturer does not accept any liability for operability,
power of the appliance or for other risks if the appliance is
operated at pressure values other than those values specified
for the appliance.
Note:
If you are operating the appliance with liquefied gas, use
a gas pressure regulator. The pressure regulator must be
connected and maintained by a licensed technician.
Positioning and levelling
Positioning the appliance
When installing the appliance, make sure that there is enough
space in the final installation location to pull the appliance
forwards for cleaning and maintenance work.
The ground underneath must be hard and firm. The wall
immediately behind the appliance must be made from non-
flammable material, e.g. tiles.
If you need to move the appliance in order to position it, make
sure that the adjustable feet are fully screwed in.
Levelling the appliance
Level the appliance once all other work has been completed.
To do this, turn the adjustable feet.
$
%
&
Type of
gas
mbar
kPa
Nozzle
Type of burner Power
(W)
Power
min. (W)
Consumption max.
Number
Bypass
G20
G30
G31
Natural
gas - NG
G20
20
2.0
115 (Y)
Gap
High output
burner
3000
800
283 l/h
97 (Z)
Gap
Standard burner 1800
500
167 l/h
72 (X)
Gap
Economy
burner
1000
400
97 l/h
135 (S)
Gap
Wok burner
3900
1600
359 l/h
Liquefied
gas - LPG
Butane
Propane
G30/G31
28 -
30/37
2.8 -
3.0/
3.7
85
0.45
High output
burner
3000
800
218 g/h
214 g/h
65
0.33
Standard burner 1800
500
131 g/h
129 g/h
50
0.30
Economy
burner
1000
400
73 g/h
71 g/h
100
0.63
Wok burner
3900
1600
284 g/h
278 g/h