19
Rating plate
The technical data for the appliance can be found on the rating
plate.
The rating plate is located on the inside of the storage
compartment flap.
The setting values are specified on a label on the appliance
packaging.
Enter the product number (E no.), production number (FD no.),
factory settings for the type of gas/gas pressure and, if
applicable, the converted gas type into the table below. The
changes made to the appliance and the type of connection are
crucial for the safe and correct operation of the appliance.
Guidelines for ventilation
This appliance may only be set up in a sufficiently ventilated
room and according to the applicable regulations and
ventilation requirements.
Please note that the air volume required for combustion must
not be below 2 m³ per kW of power (see kW total power on the
rating plate).
For appliances with a total power of up to 11 kW, it is sufficient
if the room where it is to be installed has a capacity of more
than 20 m³ and at least one door to the outside or a window
that can be opened.
Note:
In some countries, there are differing requirements
concerning the minimum capacity. Your after-sales service
department will provide you with information about this.
Installation
This appliance is always supplied with a set of adjustable feet
and, depending on the model, with a splash guard. The
appliance may also be used without the splash guard.
Fitting the adjustable feet
1.
Remove all parts that are not permanently fixed, especially
the pan supports and burners.
2.
Remove the accessories from the oven.
3.
Tilt the appliance by lifting one side from the floor.
4.
Screw the adjustable feet into the mounting holes on the
underside of the appliance. If you then have to pull the
appliance, fully screw in the adjustable feet.
5.
Only finally level the appliance when the electricity and gas
have been connected and all of the installation work has
been completed.
Electrical connection
Only a licensed expert may connect the appliance. The
appliance must be installed according to the most recent IEE
regulations (Institute of Electrical Engineers). The appliance
may be damaged if incorrectly connected.
Make sure the voltage of the power supply corresponds to the
specified value on the rating plate. The rating plate can be
found on the inside of the storage compartment flap.
Ensure that the power supply is properly earthed, and that the
fuse and the wiring and piping system in the building can
withstand the load from the appliance.
It is recommended that you configure the circuit for the
appliance to 16 A.
When you route the cable, make sure that:
■
the cable is not trapped or squashed.
■
the cable, for example, does not come into contact with
sharp edges or cutting edges.
■
the cable does not come into contact with parts that can
reach temperatures of more than 50 °C above room
temperature.
Connecting the appliance to the power supply
The appliance corresponds to protection class 1 and may only
be operated with a protective earth connection.
The appliance must be disconnected from the power supply for
all installation work.
The appliance must only be connected to the power supply with
the power cable provided.
Contact protection must be ensured by the installation.
Only a licensed expert may connect the appliance. He is
subject to the regulations of the local electricity provider.
Power cable without a plug without earthing contact
An all-pole isolating switch with at least a 3 mm contact gap
must be fitted in the installation. Identify the phase and neutral
conductors in the socket. The appliance may be damaged if
incorrectly connected.
E no.
FD no.
After-sales service
O
Type of gas/gas pressure
Factory setting
Type of gas/gas pressure
Conversion