background image

IntuiKey Keyboard

Safety | en

1

Bosch Security Systems, Inc.

Installation Manual

F.01U.115.018 | 1.92 | 2008.12

1

Safety

1.1

Important Safety Instructions

Read, follow, and retain for future reference all of the following safety instructions. Heed all 

warnings on the unit and in the operating instructions before operating the unit.

1.

Cleaning - 

Unplug the unit from the outlet before cleaning. Follow any instructions 

provided with the unit. Generally, using a dry cloth for cleaning is sufficient, but a moist 

fluff-free cloth or leather shammy may also be used. Do not use liquid cleaners or aerosol 

cleaners.

2.

Heat Sources - 

Do not install the unit near any heat sources such as radiators, heaters, 

stoves, or other equipment (including amplifiers) that produce heat.

3.

Ventilation -

 Any openings in the unit enclosure are provided for ventilation to prevent 

overheating and ensure reliable operation. Do not block or cover these openings. Do not 

place the unit in an enclosure unless proper ventilation is provided, or the manufacturer's 

instructions have been adhered to.

4.

Water - 

Do not use this unit near water, for example near a bathtub, washbowl, sink, 

laundry basket, in a damp or wet basement, near a swimming pool, in an outdoor 

installation, or in any area classified as a wet location. To reduce the risk of fire or 

electrical shock, do not expose this unit to rain or moisture.

5.

Object and liquid entry - 

Never push objects of any kind into this unit through openings 

as they may touch dangerous voltage points or short-out parts that could result in a fire 

or electrical shock. Never spill liquid of any kind on the unit. Do not place objects filled 

with liquids, such as vases or cups, on the unit.

6.

Lightning - 

For added protection during a lightning storm, or when leaving this unit 

unattended and unused for long periods, unplug the unit from the wall outlet and 

disconnect the cable system. This will prevent damage to the unit from lightning and 

power line surges.

7.

Controls adjustment -

 Adjust only those controls specified in the operating instructions. 

Improper adjustment of other controls may cause damage to the unit. Use of controls or 

adjustments, or performance of procedures other than those specified, may result in 

hazardous radiation exposure.

8.

Overloading - 

Do not overload outlets and extension cords. This can cause fire or 

electrical shock.

9.

Power cord and plug protection - 

Protect the plug and power cord from foot traffic, 

being pinched by items placed upon or against them at electrical outlets, and its exit 

from the unit. For units intended to operate with 230 VAC, 50 Hz, the input and output 

power cord must comply with the latest versions of 

IEC Publication 227

 or 

IEC Publication 

245

.

10.

Power disconnect - 

Units with or without ON/OFF switches have power supplied to the 

unit whenever the power cord is inserted into the power source; however, the unit is 

operational only when the ON/OFF switch is in the ON position. The power cord is the 

main power disconnect device for switching off the voltage for all units.

Summary of Contents for IntuiKey Series

Page 1: ...IntuiKey Keyboard Keyboard Version 1 92 en Installation Manual ...

Page 2: ......

Page 3: ...12 3 2 Connecting to the IntuiKey 13 3 3 KBD Universal RS 232 Protocol Installation 15 3 3 1 Keyboard Number Assignments when Using RS 232 Model Keyboards 15 3 3 2 Allegiant System Command Scripts for RS 232 Model Keyboards 16 3 4 Console Expander Configuration when Using RS 232 Model Keyboards 18 3 4 1 Login Feature when Using RS 232 Model Keyboards 20 3 5 IntuiKey Terminal Mode 20 3 6 Configurin...

Page 4: ...iv en Table of Contents IntuiKey Keyboard F 01U 115 018 1 92 2008 12 Installation Manual Bosch Security Systems Inc ...

Page 5: ...s of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electrical shock Never spill liquid of any kind on the unit Do not place objects filled with liquids such as vases or cups on the unit 6 Lightning For added protection during a lightning storm or when leaving this unit unattended and unused for long periods unp...

Page 6: ...g service Unplug the unit from the main AC power source and refer servicing to qualified service personnel when any damage to the equipment has occurred such as the power supply cord or plug is damaged exposure to moisture water and or inclement weather rain snow etc liquid has been spilled in or on the equipment an object has fallen into the unit unit has been dropped or the unit cabinet is damag...

Page 7: ... UL IEC60950 Any output or signal lines from the camera must be SELV or Limited Power Source For safety reasons the environmental specification of the camera lens assembly must be within the environmental specification of 10 C 14 F to 50 C 122 F Camera signal Protect the cable with a primary protector if the camera signal is beyond 140 feet in accordance with NEC800 CEC Section 60 Coax grounding G...

Page 8: ...tection must be secured with a maximum fuse rating of 16A This must be in accordance with NEC800 CEC Section 60 Grounding and polarization This unit may be equipped with a polarized alternating current line plug a plug with one blade wider than the other blade This safety feature allows the plug to fit into the power outlet in only one way If unable to insert the plug fully into the outlet contact...

Page 9: ... equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules and ICES 003 of Industry Canada These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and radiates radio frequency energy and if not installed and u...

Page 10: ...ommerciale Cette appareil génère utilise et émet de l energie de fréquence radio et peut en cas d installation ou d utilisation non conforme aux instructions générer des interférences nuisibles aux communications radio L utilisation de ce produit dans une zone résidentielle peut provoquer des interférences nuisibles Le cas échéant l utilisateur devra remédier à ces interférences à ses propres frai...

Page 11: ...ard s for Safety for Information Technology Equipment UL 60950 1 UL Certification does not cover the performance or reliability of the security or signaling aspects of this product UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT Copyright This user guide is the intellectual p...

Page 12: ...8 289 0096 Fax 585 223 9180 Email security sales us bosch com Technical Support Telephone 800 289 0096 or 800 326 1450 Fax 585 223 3508 or 717 735 6560 Email technical support us bosch com Repair Center Telephone 585 421 4220 Fax 585 223 9180 or 717 735 6561 Email security repair us bosch com Canada Telephone 514 738 2434 Fax 514 738 8480 Europe Middle East Asia Pacific Region Telephone 31 0 76 57...

Page 13: ...l video recorders System4 Multiplexers and VCRs System cameras can be controlled through any of these devices linked to the keyboard Backwards compatibility with existing Bosch products enables the IntuiKey s integration into almost any system configuration no additional devices interfaces necessary The IntuiKey user interface simplifies system programming by providing intuitive menus allowing eas...

Page 14: ...66 mm Signal Allegiant 2 wire RS 485 9600 Baud 8 bits No parity 1 Stop bit MUX DVR 2 wire RS 485 19 200 Baud 8 bits No parity 1 Stop bit RS 232 Serial Port RS 232 RTS CTS Handshaking 9600 19 200 Baud 8 bits No parity 1 Stop bit Depth 7 518 in 190 95 mm Height 2 969 in 75 41 mm Weight 2 62 lb 1 19 kg Compatibility Connectors Backwards compatible with all Allegiant systems utilizing variable speed p...

Page 15: ...e Allegiant Series of video switchers have a varying number of keyboard ports depending on model number If more than eight keyboards are required on one of the larger Allegiant Series Switchers an Allegiant keyboard expander must be added Bosch offers the following Keyboard Expanders For use with Allegiant Series Switchers LTC 8714 Keyboard Port Expander and LTC 8715 Keyboard Expander For use with...

Page 16: ...pply Greater than 100 ft 30 m LTC 8557 60 50 Keyboard Extender Divar Digital Video Recorder Series 1 2 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr PHILIPS 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr PHILIPS 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr PHILIPS 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr PHILIPS 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr PHILIPS 1 2 3 4 5 6 7 8 9 0 Shot Mon Prod Clr PHILIPS 1 2 3 4 5 6 7 8 9 0 S...

Page 17: ...own in Figure 3 9 Make the necessary keyboard data and power connections that are best suited to your system requirements based on these diagrams When connecting to a Divar Series DVR or to a System4 Multiplexer attach the supplied 390 terminator to the Out connector on the last device MUX DVR ALLEGIANT 12VDC RS 232SERIALPORT MUX DVR DC Power Allegiant RS 232 Serial Port Cable Strain Reliefs CAUTI...

Page 18: ...ble Supplied 3 m 10 ft Data Cable IntuiKey Connection Using Optional LTC 8557 Remote Hookup Kit Video Device 30 m 100 ft LTC 8558 00 Data Cable IntuiKey Connection Using Optional LTC 8558 Data Cable IntuiKey Keyboard IntuiKey Keyboard Video Device 3 m 10 ft Data Power Cable IntuiKey Connection Using Supplied Data Cable IntuiKey Keyboard Multiple Divar Digital Video Recorders or System4 Multiplexer...

Page 19: ... on the interface connection type of the RS 232 keyboard Keeping track of these keyboard numbers is necessary when priority based restrictions or other keyboard related lockouts are assigned and used in the system The table below indicates which keyboard number will be assigned based on the connection being used i NOTICE On initial power up factory reset or firmware upgrade the IntuiKey displays t...

Page 20: ...le port to operate in the keyboard mode it is necessary to connect to the system via Windows HyperTerminal or another dumb terminal emulator The Allegiant RS 232 settings are user programmable but the default settings are Baud 19 200 Stop bits 1 Data bits 8 Parity None Handshake None Once online with the system an Allegiant prompt appears each time Enter is pressed The prompt looks as follows TC8x...

Page 21: ...ODE 4 1 Modem connected to Console port except LTC 8900 Command SET PORT RS232 0 4 8 0 1 1 _SET_KBD_MODE 0 1 Modem connected to Printer port except LTC 8900 Command SET PORT RS232 4 4 8 0 1 1 _SET_KBD_MODE 4 1 Direct to Controller port LTC 8900 only Command SET PORT RS232 0 4 8 0 1 0 _SET_KBD__MODE 0 1 Direct to Console port LTC 8900 only Command SET PORT RS232 4 4 8 0 1 0 _SET_KBD_MODE 4 1 Modem ...

Page 22: ...el Keyboards RS 232 model keyboards may be connected to an Allegiant system using the LTC 8712 Series Console Port Expander as shown in Figure 3 7 An LTC 8712 Series Console Port Expander can be configured to support up to four RS 232 Keyboard connections Other devices such as a PC running the Allegiant Master Control software can be connected to the unused ports of the Port Expander Because the P...

Page 23: ...use either the Allegiant Keyboard User Function 38 or the Master Control Software to change the port to the Port Expander mode If using the Master Control Software connect to the Allegiant and go online Select the Parameter tab and then the Options tab Check the box labeled Set Printer Port to Port Expander mode Download the table into the Allegiant Set the internal dipswitches of the LTC 8712 Con...

Page 24: ...tely determined by the third party software running on a PC All communication between the keyboard and the third party PC is performed through an RS 232 interface The following diagram illustrates this configuration Figure 3 8 Terminal Mode This connection requires a standard Null modem RS 232 link If desired the Bosch Security Systems cable S1385 can be used Connect one end of the RS 232 interfac...

Page 25: ...se Normal black on white MUX Destination Addr 1 Softkey Contrast 9 Status Display Contrast 6 MUX User Level No Access Language NONE Allegiant Baud 9600 Protocol This password protected option is used to set the Allegiant communication protocol Default is RS 485 When using a Terminal Mode connection leave this parameter at its default setting See Appendix A for details on entering passwords Languag...

Page 26: ...les one for the Softkey display and the other for the status display Control each adjustment scale with the adjacent softkey buttons as indicated by the arrows in the menu Generally the buttons to the right of each scale decrease the contrast make the display lighter while the buttons to the left increase the contrast make the display darker The indicator on the scale is incremented moved one step...

Page 27: ...n the product menu DVR or multiplexer is missing Unique address has not been set in the video devices Use the front panel controls to access the appropriate on screen menu to assign address and starting camera numbers The IntuiKey will not properly recognize video devices if there are conflicting addresses in the system Check all interconnect cables for cut or broken wires between the keyboard and...

Page 28: ...the Advanced Menu softkey 3 The joystick does not appear to work Ensure that you are controlling a movable camera Ensure that all cabling is correct It is possible that the joystick needs to be recentered From the Product menu select KEYBOARD CONTROL and press the JOYSTICK AUTOCAL softkey then follow the on screen instructions 4 4 Miscellaneous 1 Upon powering up the keyboard the bootloader screen...

Page 29: ...out AutoDome Security The AutoDome contains security features to restrict access to its Advanced Menu To obtain access to the Advanced Menu enter an Auxiliary Off 90 command If no password has been set the AutoDome s default password of 0000 four zeros allows the Auxiliary Off 90 command to directly unlock the security feature to the Advanced Menu commands After a period of thirty 30 minutes the A...

Page 30: ...26 en IntuiKey Keyboard F 01U 115 018 1 92 2008 12 Installation Manual Bosch Security Systems Inc ...

Page 31: ......

Page 32: ...curity Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securitysystems bosch com www boschsecurity com Bosch Security Systems Inc 2008 F 01U 115 018 1 92 2008 12 Data subject ...

Reviews: