Assembly
Place down the battery pack only on clean surfaces.
In particular, avoid soiling the charge socket and the con-
tacts, e.g. by means of sand or soil.
Checking the Battery Pack
Before Using for the First Time
Check the battery pack before charging it or using it with your
eBike for the first time.
For this, press the On/Off button
A4
to switch on the battery
pack. When no LED of the charge-control indicator
A3
lights
up, the battery pack may be damaged.
When at least one, but not all LEDs of the charge-control indi-
cator
A3
is lit, then fully charge the battery pack before using
for the first time.
Do not attempt to charge or use a damaged battery
pack.
Please refer to an authorised Bosch eBike dealer.
Charging the Battery Pack
Use only the Bosch charger provided with your eBike or
an identical original Bosch charger.
Only this charger is
matched to the lithium-ion battery pack used in your eBike.
Note:
The battery pack is supplied partially charged. To en-
sure full battery pack capacity, completely charge the battery
pack in the charger before using for the first time.
For charging the battery pack, read and observe the operating
instructions of the charger.
The battery pack can be recharged at any time on its own or on
the bike without shortening the lifespan. Interrupting the
charging process does not damage the battery pack.
The battery pack is equipped with a temperature control indi-
cator, which enables charging only within a temperature
range between 0 °C and 40 °C.
When the battery pack is not
within the charging-tempera-
ture range, three LEDs of the
charge-control indicator
A3
flash. Disconnect the battery pack from the charger until its
temperature has adjusted.
Do not connect the battery pack to the charger until it has
reached the allowable charging temperature.
Charge-control Indicator
When the battery pack is switched on, the five green LEDs of
the charge-control indicator
A3
indicate the charge condition
of the battery pack.
In this, each LED indicates approx. 20 % capacity. When the
battery pack is completely charged, all five LEDs light up.
The charge level of the switched on battery pack is also shown
on the display of the on-board computer. When doing so, read
and observe the operating instructions of the drive unit and
on-board computer.
If the capacity of the battery pack is below 5 %, all LEDs of the
charge-control indicator
A3
on the battery pack go out. Howev-
er there is another display function of the on-board computer.
Lithium ion battery pack
PowerPack 300
PowerPack 400
Article number
– Standard battery pack
– Rack-type battery pack
0 275 007 509
0 275 007 511
0 275 007 513
0 275 007 510
0 275 007 512
0 275 007 514
0 275 007 522
Rated voltage
V=
36
36
Rated capacity
Ah
8.2
11
Energy
Wh
300
400
Operating temperature
°C
–10...+40
–10...+40
Storage temperature
°C
–10...+60
–10...+60
Allowable charging temperature range
°C
0...+40
0...+40
Weight, approx.
kg
2.0/2.4
2.5/2.6
Degree of protection
IP 54 (dust and splash
water protected)
IP 54 (dust and splash
water protected)
OBJ_BUCH-2087-002.book Page 10 Wednesday, July 16, 2014 5:12 PM