background image

en

    Installation

18

Electrical connection

:

Warning – Risk of electric shock! 

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

The required connection data can be found on the 

rating plate inside the appliance; to do this, remove the 

metal mesh grease filter.

Length of the cable: approx. 1.30 m

This appliance complies with the EC interference 

suppression regulations.

:

Warning – Risk of electric shock! 

It must always be possible to disconnect the appliance 

from the electricity supply. The appliance must only be 

connected to a protective contact socket that has been 

correctly installed. 

The mains plug of the mains power cable must be 

easily accessible after installation of the appliance. If 

this is not possible, an all-pole isolating switch must be 

integrated into the permanent electrical installation 

according to the conditions of overvoltage category III 

and according to the installation regulations.

The permanent electrical installation must only be wired 

by a professional electrician. We recommend installing 

a residual-current circuit breaker (RCCB) in the 

appliance's power supply circuit.

5

Installation

Installation

Fitting the upper support frame

1.

Before fitting, determine the total height of the 

support frame and mark the screw holes.

Note: 

The height of the support frame can be 

adjusted in 20 mm intervals.

2.

On the ceiling, mark the centre point of the 

appliance.

3.

Using the enclosed template, mark the positions for 

the screws on the ceiling.

4.

Drill four 8 mm diameter holes to a depth of 80 mm 

for the fasteners and press in the wall plugs flush 

with the ceiling.

5.

Fasten the upper part of the support frame to the 

ceiling with 4 screws.

Note: 

Ensure that the support frame is in the correct 

position. The middle bracket defines the preferred 

side and must be facing the hob control elements.

Fitting the lower support frame

Fasten the upper and lower part of the support frame at 

the specified total height using 10 screws.

Notes

Ensure that the lower support frame is in the correct 

position. The open side must be facing the hob 

control elements.

The support frame can be subsequently re-

positioned by loosening the securing screws.

[

[

[

([KDXVWDLU

PP

&LUFXODWHGDLU

PP

[

Summary of Contents for iQ700 LF91BUV50B

Page 1: ...Extractor hood en Instructions for installation and use ...

Page 2: ......

Page 3: ... perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea ...

Page 4: ...ndows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the g...

Page 5: ...k Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while ...

Page 6: ...onmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible...

Page 7: ...res slide your finger to the left across control panel III to select the fan setting you require Lighting The lighting can be switched on and off independently of the fan Touch the symbol Setting the brightness Press and hold the symbol until the desired brightness is reached Boost function Switching on Touch the symbol Note After approximately 20 seconds the extractor hood automatically switches ...

Page 8: ...s and activated charcoal filter and If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning and maintenance on page 12 Note The saturation indicator does not apply for non renewable activated charcoal filters that are inserted downstream of the metal grease filter These activated charcoal filters must be replaced twice a year Th...

Page 9: ...a the hood controls on the hob If the extractor hood is being operated by means of the controls on the hood itself this mode of operation always has priority It is not possible to use the hood controls on the hob during this time Setting up a connection The hood must be switched off before you can connect the hob and extractor hood Connecting directly Make sure that the hob is switched on and is i...

Page 10: ...nually logging into your home network The extractor hood cannot be switched on during the connection process You can cancel the process at any time by pressing the symbol To connect the extractor hood to your home network the hood and the light must be switched off 1 Press and hold the symbol until the D and Ù indicators start flashing 2 To start automatic login to your home network swipe right ov...

Page 11: ...ote For more information and to check whether the remote diagnostics service is available in your country please visit the Help Support area of the Home Connect website for your country www home connect com Resetting the connection You can reset the connections you have saved on your home network and on Home Connect at any time Press and hold the and symbols until the D symbol goes out When the au...

Page 12: ...e Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your other hand 2 Take the metal grease filter out of the h...

Page 13: ... rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Pla...

Page 14: ...isit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Accessories not included in the scope of delivery Note These instructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for y...

Page 15: ...r is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers W...

Page 16: ...ncoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or...

Page 17: ...es that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances If the exhaust air is to be conveyed into a non functioning smoke or exhaust gas flue you must obtain the consent of the heating engineer responsible If the exhaust air is conveyed through the outer...

Page 18: ...ation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit 5Installation InstallationFitting the upper support frame 1 Before fitting determine the total height of the support frame and mark the screw holes Note The height of the support frame can be adjusted in 20 mm intervals 2 On the ceiling mark...

Page 19: ...nd seal Exhaust air pipe Ø 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective f...

Page 20: ...Carl Wery Str 34 81739 München GERMANY BSH Hausgeräte GmbH siemens home bsh group com 9001359533 9001359533 990731 Manufactured by BSH Hausgeräte GmbH under Trademark License of Siemens AG ...

Reviews: