6.0   Specifications 

 

Table 5:  Specifications 

 

Power Supply 

9 VDC to 28 VDC, non-polarized 

Current Draw 

25 mA 

Coverage 

ISN-CP1-CM-W50: Wide angle,  
14 m (43 ft) maximum range, 
15 zone pairs, 30 fingers 

ISN-CP1-CM-N100: Long range,  
30 m (93 ft) maximum range, 8 zone 
pairs, 16 fingers 

Operating 
Temperature and 
Humidity 

–20º C (–4º F) to +50º C (+122º F), 
95% RH or less, non-condensing 

Alarm Contacts 

One selectable Form 1A (NO) or 
1B (NC) semiconductor relay,  
0.1 A at 30 VDC 

Tamper Contacts 

One Form 1B (NC), 0.1 A at 30 VDC

Alarm LED 
Indication (Red) 

Flashes when power is first applied 
and when the detector initiates self-
diagnosis. Lights when the detector 
activates an alarm. 

Mirror Angle 
Adjustment 

30º vertically (ISN-CP1-CM-W50) 

33º vertically (ISN-CP1-CM-N100) 

Weight 

190 g (6.7 oz) 

 

 

For UL Certificated installations, you must 
set the sensitivity to 100% or 120%. You 
must set the pulse count to 1. 

 

 

 
 

Summary of Contents for ISN-CP1-CM-W50

Page 1: ...EN Installation Instructions PIR Detector ISN CP1 CM W50 ISN CP1 CM N100 ...

Page 2: ...por or high humidity that can cause condensation Mount the detector on 2 5 m 8 2 ft to 5 m 16 4 ft ceilings Install the detector so that intruders cross the coverage pattern Do not install the detector where pets are present Avoid installing the detector where cabinet doors curtains or other objects that can swing or move are within the coverage pattern 2 0 Installation Do not apply power until af...

Page 3: ...s 7 Spare No connection Refer to Table 2 to determine the minimum gauge wire required between the power source and the detector The table is based on one detector connected to a 12 VDC power source Table 2 Wiring Specifications Wire Gauge Maximum Length 0 3 mm2 AWG 22 700 m 2250 ft 0 5 mm 2 AWG 20 1200 m 3900 ft 0 75 mm2 AWG 18 1800 m 5900 ft When adding two or more detectors to a wire run the max...

Page 4: ... pyro sensor or the amplifier The Alarm output operates when this fault condition occurs 2 For UL Certificated installations you must set the sensitivity to 100 or 120 You must set the pulse count to 1 3 The detector activates an alarm when the count reaches the number of specified pulses within an interval of 10 sec or less The unit resets the count 10 sec after the last pulse As a guide set a pu...

Page 5: ...ft 46 ft 0 m 2 m 4 m 6 m 8 m 10 m 12 m 14 m 46 ft 39 5 ft 33 ft 26 5 ft 20 ft 13 ft 6 5 ft 0 ft 1 60 0 m 2 5 m 0 ft 8 ft 0 m 5 m 10 m 14 m 0 ft 33 ft 46 ft 2 16 5 ft 1 Top view 2 Side view Figure 6 ISN CP1 CM N100 Coverage Patterns 0 m 5 m 10 m 15 m 20 m 25 m 30 m 0 ft 16 5 ft 33 ft 49 ft 65 5 ft 82 ft 98 5 ft 0 m 2 8 m 0 ft 9 2 ft 1 0 m 5 m 10 m 15 m 20 m 25 m 30 m 0 ft 16 5 ft 33 ft 49 ft 65 5 f...

Page 6: ...magnetic noise or is wired too close to a power source Relocate the detector Reroute the wiring Sudden temperature fluctuation Exposed to direct sunlight Remove the heat source Readjust the coverage Block the light with blinds The detector body is not attached to the base Attach the detector body firmly on the base Alarm LED lights but there is no alarm output Controller not armed Arm the controll...

Page 7: ...rating Temperature and Humidity 20º C 4º F to 50º C 122º F 95 RH or less non condensing Alarm Contacts One selectable Form 1A NO or 1B NC semiconductor relay 0 1 A at 30 VDC Tamper Contacts One Form 1B NC 0 1 A at 30 VDC Alarm LED Indication Red Flashes when power is first applied and when the detector initiates self diagnosis Lights when the detector activates an alarm Mirror Angle Adjustment 30º...

Page 8: ... 2005 Bosch Security Systems 4998154997B Bosch Security Systems 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 ...

Reviews: