38
en | wLSN Devices
wLSN
F01U138553 | 01 | 2010.05
System Reference Guide
Bosch Security Systems, Inc.
DIP Switch Settings
Use the DIP switches on the outdoor siren to configure it to
comply with the installation laws of the locale.
Figure 5.13
wLSN Outdoor Siren DIP Switches
Table 5.16
DIP Switch Settings for wLSN Outdoor Siren
OFF
ON
Switch 1
Switch 2
Configuration
OFF
OFF
Default configuration
–
Siren is limited to 90 sec.
–
Flashes every 1.5 sec from 0-90 sec of the alarm
–
Flashes every 3 sec from 90 sec to 30 min of the alarm
–
Flash stops after 30 min
ON
OFF
–
Siren activates for 60 sec followed by 30 sec of silence,
then activates again for 60 sec
–
Flashes every 1.5 sec from 0 to 150 sec of the alarm
–
Flashes every 3 sec from 150 sec to 30 min of the alarm
–
Flash stops after 30 min
ON
ON
–
Siren is limited to 90 sec
–
Flashes every 1.5 sec from 0 to 90 sec of the alarm
–
Flashes every 3 sec from 90 sec to 30 min of the alarm
–
Flashes every 20 sec from 30 min of the alarm until the
siren is turned off
OFF
ON
Reserved for future use.