Type L 309
Power Supply Module
Technical data
4
1070 078 131-104 (00.05) GB
Thyristor off-state voltage:
2000 V
Overvoltage protection:
by MOV (metal-oxide varistor)
Electrical connection:
Mains connection L1* as auxiliary phase with
6.3 mm flat connector.
Mains connection L2 with bolt
M8 (
Types L 309.150/151
) or
M10 (
L 309.250
).
Welding transformer connection V with bolt
M10
Connection to timer unit:
via 12-pin plug-in connector
Cooling:
Water cooling without internal piping.
Water inlet temperature:
max. 30
°
C
Water throughput:
4 liters/min.
Differential inlet-outlet:
1 bar at 4 liters/min.
Cooling thermostatically controlled
Water connection:
Inlet / outlet: R 3/8”, 37
°
female taper
Fault messages:
Thermostatic switch signal, floating relay con-
tact; it is evaluated by the timer which outputs
the fault message: ”Overtemperature - power
supply fault”
Monitoring:
Feedback transformer. Primary voltage of the
welding transformer is reduced to 24 V A.C.
Display:
Incoming firing pulses are indicated by yellow
LED - 5 kHz firing
Summary of Contents for L 309 Series
Page 1: ...Power Supply Module Technical Information L 309 150 L 309 250 104 Edition ...
Page 3: ......
Page 5: ...Flexible Automation Type L 309 Power Supply Module 1070 078 131 104 00 05 GB ...
Page 15: ...Flexible Automation Type L 309 Power Supply Module Structure 2 1070 078 131 104 00 05 GB ...
Page 27: ...Maintenance Type L 309 Power Supply Module 14 1070 078 131 104 00 05 GB ...
Page 31: ...Dimensioning instructions Type L 309 Power Supply Module 18 1070 078 131 104 00 05 GB ...
Page 33: ...Fault messages Type L 309 Power Supply Module 20 1070 078 131 104 00 05 GB ...
Page 36: ...A 1 1070 078 131 104 00 05 GB 1070 078 131 104 00 05 GB TI WS AT VWS Printed in Germany ...