Connection instructions
Type L 309
Power Supply Module
11
1070 078 131-104 (00.05) GB
5.3. Connection to the timer module
The connection between the L 309 power supply module and the PSS... or PSH ...
timer module (PSL, UPR connections) is made via terminal connector X1.
The terminal for X1 is included in the delivery. Max. clampable wire cross-section:
1.5 mm
2
.
Required conductor cross-sections:
up to 10 m:
0.75 mm
2
up to 75 m:
1.5 mm
2
L309/X1
1
2
3
4
5
6
7
8
9
10
11
12
27VA.C.
27VA.C.
operational earth
floatingrelaycontact(thermostaticswitch)
weld+
weld−
+24VD.C.
0V
primaryvoltagefeedbackUPR1
totimer
PSS.../PSH...
F1(M1.25A)
F2(M2.5A)
floatingrelaycontact(thermostaticswitch)
floatingrelaycontact(thermostaticswitch)
primaryvoltagefeedbackUPR2
CAUTION!
- The X1 connection may only be made or removed when the unit is safely iso-
lated from supply!
NOTE
Provide wire ends with end sleeves and properly tighten the terminals!
The connection cable is
not
included in the delivery!
X1
1
12
!
Summary of Contents for L 309 Series
Page 1: ...Power Supply Module Technical Information L 309 150 L 309 250 104 Edition ...
Page 3: ......
Page 5: ...Flexible Automation Type L 309 Power Supply Module 1070 078 131 104 00 05 GB ...
Page 15: ...Flexible Automation Type L 309 Power Supply Module Structure 2 1070 078 131 104 00 05 GB ...
Page 27: ...Maintenance Type L 309 Power Supply Module 14 1070 078 131 104 00 05 GB ...
Page 31: ...Dimensioning instructions Type L 309 Power Supply Module 18 1070 078 131 104 00 05 GB ...
Page 33: ...Fault messages Type L 309 Power Supply Module 20 1070 078 131 104 00 05 GB ...
Page 36: ...A 1 1070 078 131 104 00 05 GB 1070 078 131 104 00 05 GB TI WS AT VWS Printed in Germany ...