Connector and wiring details
All VARI input and output connectors are located in the connector compartment at the bottom
of the VARI‑B or VARI‑BH base unit. The IEC AC mains socket is immediately adjacent.
Except for the mains connection, all other connections to the VARI base unit are made via
Phoenix-type screw‑terminal connectors. All mating connectors are supplied; note that three
different sizes are used. All connectors on the VARI have male contacts.
The pinouts of each connector are given in the next paragraphs.
Figure
5.1: Base unit connectors
Figure
5.2: Base unit connector overview
Reference
Connector
Reference
Connector
1
AC mains input
7
Input 2 (100 V)
2
Backup DC power supply input 8
RS-485 network input
3
Fuse (for 24 V input only)
9
RS-485 network thru
4
Input 1 (line level)
10
External control input
5
Input 2 (line level)
11
Failure relay
6
Input 1 (100 V)
12
CobraNet®/Ethernet port *
* Only present if CobraNet® module is fitted.