VARI-directional array
Technical Data | en
39
Bosch Security Systems B.V.
Installation manual
2018.06 | V1.3 |
Electrical
Input Line (2x)
Input level nominal
0
dBV rms
Input level maximum
+20
dBV peak
Type
Transformer balanced
Impedance (balanced)
7.8
kohm at 1
kHz
Input 100
V (2x)
Input level nominal
+40
dBV rms
Type
Transformer balanced (floating input)
Impedance (balanced)
1
Mohm at 1
kHz
Power Amplifiers
Power
VARI‑B(H)
8
x
15
W (class‑D full bridge)
VARI‑E
4
x
25
W (class‑D full bridge)
Protection
Thermal shutdown
Current limiting
Dynamic range
6
>105
dB
PSU
Mains voltage
100 to 120
V / 200 to 240
V (auto switching)
Power consumption
@
Mains
/
24
Vdc (22 V min, 36 V max)
Power save
VARI‑B(H)
13
/
4.5
W
VARI‑B(H)+E
17
/
7
W
VARI‑B(H)+E+E
19
/
9
W
Idle
VARI‑B(H)
18
/
8.5
W
VARI‑B(H)+E
23
/
13
W
VARI‑B(H)+E+E
28
/
17
W
Max. (Noise, CF 6
dB)
VARI‑B(H)
60
/
36
W
VARI‑B(H)+E
97
/
75
W
VARI‑B(H)+E+E
124
/
100
W
Power factor
According to EN61000‑3‑2, class
A