40
en | Technical Data
VARI-directional array
2018.06 | V1.3 |
Installation manual
Bosch Security Systems B.V.
Mains inrush current
<70
A (at 230
V)
Protection
Thermal shutdown
Current limiting
Under voltage lock‑out
Signal processing
5
DSP
32‑bit floating point, 900 Mflops
ADC / DAC
24‑bits S‑D, 128
x
oversampling
Sample rate
48
kHz
Functions
Pre‑delay (max. 21
s)
Input‑delay (max.
2
x
10
s
/
4
x
5
s)
Equalizer and compensation filtering
Compressor
Volume
AVC
Control
Network interface
RS‑485 full duplex, auto‑switching 115k2, 57k6, 38k4,
19k2 baud, optically isolated
Max. number of units
7
126
Surveillance
General status
Amplifier and load monitoring
External pilot‑tone detection
(20
kHz to 30
kHz, min. level -22
dBV)
Built‑in ambient noise sensing microphone
Thermal overload protection
Failure relay
Maskable conditions
Contact 1
No failure = closed / Failure = open
Rating
Max. 24
V, 100
mA
Contact 2
No failure = 10
k ohm / Failure = 20
k
ohm
Control voltage input
5 to 24
Vdc, optically isolated
CobraNet
Interface
RJ‑45, Ethernet 100
Mbps