MIC Series IP Power Supply
Configuration using a Web browser | en
33
Bosch Security Systems, Inc.
User Manual
F.01U.265.804 | 1.6 | 2012.08
Enter the IP address of a time server here.
Time server type
Select the protocol that is supported by the selected time server. Preferably, you should
select SNTP server as the protocol. This supports a high level of accuracy and is required for
special applications and subsequent function extensions.
Select Time server for a time server that works with the protocol RFC 868.
4.5
Basic Mode: Network
The settings on this page are used to integrate the encoder into an existing network.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes
to Set and Reboot.
1.
Make the desired changes.
2.
Click the Set and Reboot button. The encoder is rebooted and the changed settings are
activated.
DHCP
If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you
can activate acceptance of IP addresses automatically assigned to the encoder.
Certain applications (for example, Bosch Video Management System) use the IP address for
the unique assignment of the unit. If you use these applications, the DHCP server must
support the fixed assignment between IP address and MAC address, and must be
appropriately set up so that, once an IP address is assigned, it is retained each time the
system is rebooted.
IP address
Enter the desired IP address for the encoder in this field. The IP address must be valid for the
network.
Subnet mask
Enter the appropriate subnet mask for the selected IP address here.
Gateway address
If you want the unit to establish a connection to a remote location in a different subnet, enter
the IP address of the gateway here. Otherwise leave the box blank (
0.0.0.0
).
CAUTION!
If you change the IP address, subnet mask or gateway address, the encoder is only available
under the new addresses after the reboot.