MIC Series IP Power Supply
Configuration using a Web browser | en
71
Bosch Security Systems, Inc.
User Manual
F.01U.265.804 | 1.6 | 2012.08
4.40
Alarm E-Mail
As an alternative to automatic connecting, alarm states can also be documented by e-mail. In
this way it is possible to notify a recipient who does not have a video receiver. In this case, the
encoder automatically sends an e-mail to a previously defined e-mail address.
Send alarm e-mail
Select On if you want the unit to automatically send an alarm e-mail in the event of an alarm.
Mail server IP address
Enter the IP address of a mail server that operates on the SMTP standard (Simple Mail
Transfer Protocol). Outgoing e-mails are sent to the mail server via the address you entered.
Otherwise leave the box blank (
0.0.0.0
).
SMTP user name
Enter a registered user name for the chosen mailserver here.
SMTP password
Enter the required password for the registered user name here.
Format
You can select the data format of the alarm message.
–
Standard (with JPEG)
E-mail with JPEG image file attachment.
–
SMS
E-mail in SMS format to an e-mail-to-SMS gateway (for example, to send an alarm by cell
phone) without an image attachment.
Image size
The size of the image. Options are: Small, Medium, Large.
CAUTION!
When a cellphone is used as the receiver, make sure to activate the e-mail or SMS function,
depending on the format, so that these messages can be received.
You can obtain information on operating your cellphone from your cellphone provider.