Danger to life, risk of injury due to electric
shock. High electric voltage over 50 volt.
WARNING
●
De-energize the part of the installation before you mount the motor-
pump-unit or connector or terminal box connections.
●
Secure the plant against restarting.
●
Do measures and tests only with firmly connected protective conductor
of components on the provided points.
●
Please always wait 30 minutes after switch-off, so live capacitors dis‐
charge before they have access to electric components. To exclude an‐
dy danger due to any contact, measure electric voltage of live parts be‐
fore working.
●
Do not touch any electric junctions of live components.
Danger to life, risk of injury due to electric
shock. High housing voltage and high dis‐
charge current.
WARNING
●
Before switch-on and start-up, ground or connect the components of the
motor-pump-unit with the protective conductors on the grounding points.
●
Connect the protective conductors of the motor-pump-unit components
always fix and continuously with the external supply network. The dis‐
charge current is bigger than 3.5 mA.
●
Use min. 10mm² copper cross-section for the total path of the protective
conductor.
Danger of fire, explosion and pollution due to
existing oil dust due to defective or improper‐
ly assembled sealings!
WARNING
●
Do not do any welding on or near pressurized motor-pump-units.
●
Keep away open fire or ignition source from motor-pump- units.
Risk of burns, risk of injury due to hot surfa‐
ces of the motor-pump-unit.
CAUTION
●
Do only touch surfaces of the motor-pump-unit with protective gloves or
do not work on hot surfaces. During or after operation, temperatures can
be over 60°C (140°F).
●
Before accessing, letz the motor-pump-unit cool down für a sufficiently
long time.
●
Observe the protective measures of the plant manufacturer.
DOK-SYTROX-MPAS1******-IT01-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPAS1
Bosch Rexroth AG
21/83
Safety Notes