Connection
8.1
Motor-Pump Unit Hydraulically Connected
●
Remove the flange covers on suction and pressure connection.
●
Immediately wipe away outgoing hydraulic fluid.
●
Check the line for cleanliness.
●
Ensure that the line connection contains the specified sealings.
●
Lock O-rings with assembly grease against slipping , if necessary.
●
Now, hydraulically connect the pump according to the specifications of
the machine manufacturers.
For further information refer to mounting instruction: Rexroth Sytronix Motor-
Pump Unit MPAS1 PGM4 - MSK101 - Air Cooling
Material number: R911342449
8.2
Ready-made Connection Cables for MPAS1
MPAS1-PGM4NE-___NNNN-V__-
110CBHA
110DBHA
110EBHA
110FBHA
HCS02.1E
W0054
RKL0067
W0070
RKL0067
RKL0069
HCS03.1E
W0070
RKL0067
RKL0069
RKL0071
RKL0079
W0100
RKL0070
RKL0072
RKL0073
W0150
RKL0072
RKL0073
HMS01.1N
W0036
RKL0075
W0054
RKL0067
RKL0069
W0070
RKL0069
RKL0071
W0110
RKL0070
RKL0072
RKL0073
W0150
RKL0072
RKL0073
Tab. 8-1:
Ready-made Connection Cables
Encoder Cables
The encoder cable used is RKG0047.
The order designation of ready-made cables consist of cable
number and length (e.g. RKL0047/010.0 for a cable length of 10.0
m).
DOK-SYTROX-MPAS1******-IT01-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPAS1
Bosch Rexroth AG
45/83
Connection
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01