8.3
Connect Motor-Pump Unit Electrically (Frame size M11)
Danger! Electric voltage! Operations in the vi‐
cinity of live parts are extremely dangerous.
WARNING
Work required on the electric system may only be carried out by skilled elec‐
tricians. Tools for electricians (VDE tools) are absolutely necessary.
Prior to commencing work:
1. Isolate (even auxiliary circuits).
2. Protect the system or plant against restart.
3. Ensure de-energization.
4. Ground and short-circuit.
5. Cover or shield any adjacent live parts.
Before starting to work, check with an appropriate measuring device whether
parts of the system are still under residual voltage (e.g. caused by capacitors,
etc.). If yes, wait until these parts have discharged.
High electrical voltage! Danger to life, risk of
injury due to electric shock.
WARNING
While the rotor is rotating, motors with permanent magnet ex‐
citation create a voltage > 60 V at the motor connections.
All work must be carried out at motor standstill.
An operation of motors is only allowed with respective converters. Direct con‐
nection on the three-phase current is not allowed and can lead to damage of
the motor.
Never touch the connection points of electro‐
static sensitive devices!
NOTICE
Installed components (e.g., KTY84, encoder) may contain
electrostatic sensitive devices (ESD).
Observe ESD safety measures.
Bosch Rexroth AG
DOK-SYTROX-MPAS1******-IT01-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPAS1
46/83
Connection
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01