24
en | Installation
FLEXIDOME HD
AM18-Q0615 | v1.0 | 2012.10
Installation Manual
Bosch Security Systems
5.3
Connections
5.3.1
Make the connections
The unit has connection terminals on flying leads. In wet or
outdoor installations make use of a field wiring box with
NEMA Type 4X or IP66 protection level or better. Make the
connections inside a water tight compartment. Isolate unused
power wires individually. After connections are made ensure
that the watertight compartment is tightly closed and cables
and conduits are properly sealed to prevent ingress of water.
Cable tree
Use the following table to identify the wires in the cable tree:
For connections use wires of at least the same thickness.
CAUTION!
Isolate unused power wires individually.
Check the type label on the rear of the camera module for the
correct power ratings.
Wire color
AWG
Signal
Red
26
+12 VDC / 24 VAC
Brown
26
-12 VDC / 24 VAC
Yellow / Green
24
Earth
Black / Orange
28
Alarm Out A
White / Orange
28
Alarm Out B
White / Violet
28
Ground (Alarm In + Data)
Orange / Violet
28
Alarm In 1
Violet
28
Alarm In 2
White
28
Audio In
(Shield)
28
Ground (Audio In)
Black 28
Audio
Out
(Shield)
28
Ground (Audio Out)