background image

For more information visit

www.boschsecuritysystems.com

© Bosch Security Systems B.V.

Data subject to change without notice

2008-01 | PLE-2CS en

Summary of Contents for PLE?2CS Plena

Page 1: ...Installation and User Instructions PLE 2CS en Plena Two zone Call Station ...

Page 2: ...guards en 2 Important safeguards Before installing or operating this product always read the Safety Instructions which are available as a separate document 9922 141 7014x These instructions are supplied together with all equipment that can be connected to the mains Thank you for choosing a Bosch Security Systems product ...

Page 3: ...s and status LEDs 7 2 3 4 PTT button 7 2 4 Controls connectors and indicators 8 2 4 1 Top side 8 2 4 2 Bottom side 8 3 Installation 9 3 1 Unpack unit 9 3 2 Connect unit to PLE series two zone mixer amplifier 9 3 3 Make configuration settings 9 4 Connections and settings 11 4 1 Connecting multiple call stations 11 4 2 Configuration settings 11 4 2 1 Chime settings 11 4 2 2 Momentary or latching spe...

Page 4: ...Bosch Security Systems 2008 01 PLE 2CS en Plena Two zone Call Station Installation and User Instructions Table of contents en 4 Intentionally left blank ...

Page 5: ...the effect that may be caused if it is not observed These alerts from least severe effect to most severe effect are Note Alert containing additional information Usually not observing a note alert does not result in damage to the equipment or personal injuries Caution The equipment can be damaged if the alert is not observed Warning Persons can be severely injured or the equipment can be seriously ...

Page 6: ...verted to non metric units using the following information table 1 1 Conversion of units of length 1 in 25 4 mm 1 mm 0 03937 in 1 in 2 54 cm 1 cm 0 3937 in 1 ft 0 3048 m 1 m 3 281 ft 1 mi 1 609 km 1 km 0 622 mi table 1 2 Conversion of units of mass 1 lb 0 4536 kg 1 kg 2 2046 lb table 1 3 Conversion of units of pressure 1 psi 68 95 hPa 1 hPa 0 0145 psi Note 1 hPa 1 mbar table 1 4 Conversion of unit...

Page 7: ...na Two zone Call Station features a selectable microphone gain level a selectable speech filter and a limiter for improved intelligibility a balanced line level output See section 2 3 1 two loop through RJ 45 sockets See section 2 3 2 DIP switches and status LEDs See section 2 3 3 a push to talk PTT button See section 2 3 4 For a detailed description of all controls connections and indicators see ...

Page 8: ...atus of the call station See section 2 3 3 2 4 2 Bottom side See figure 2 2 for an overview of the controls and indicators at the bottom of the call station 1 Configuration settings A set of DIP switches to configure the call station by setting the microphone gain level the chime and the speech filter See section 4 2 2 System sockets Two redundant RJ 45 sockets to connect the call station to the P...

Page 9: ...y peel off the protective plastic film Do not use sharp or pointed objects 3 2 Connect unit to PLE series two zone mixer amplifier 1 Connect the Plena Two zone Call Station to the PLE series two zone mixer or mixer amplifier using a Cat 5 Ethernet cable see figure 3 1 Either one of the RJ 45 sockets can be used 3 3 Make configuration settings 1 Make the configuration settings see section 4 2 figur...

Page 10: ...Bosch Security Systems 2008 01 PLE 2CS en Plena Two zone Call Station Installation and User Instructions Installation en 10 Intentionally left blank ...

Page 11: ...ary or latching speaking setting See figure 4 2 DIP switch number 4 is used for setting the momentary or latching speaking function 1 latching 0 momentary 4 2 3 Speech filter setting See figure 4 2 DIP switch number 5 is used for setting the speech filter ON 1 of OFF 0 Note In such a daisy chain configuration the priority is automatic the call station nearest to the mixer has priority and can over...

Page 12: ... 4 Microphone gain settings See figure 4 2 DIP switches number 6 and 7 are used for setting the microphone gain 1 ON position 0 OFF position table 4 2 Microphone gain settings DIP switch setting 6 7 Description 0 0 15 dB 1 0 0 dB 0 1 6 dB 1 1 6 dB figure 4 2 DIP switches ON 1 DIP OFF 0 1 2 3 4 5 6 7 8 spare ON 1 2 3 4 5 6 7 8 ...

Page 13: ...g function 1 Shortly press the push to talk button to start the business call 2 Make the business call 3 Shortly press the push to talk button to stop the business call 5 3 Adjust the call station output volume 1 Use a screw driver to adjust the output volume of the call station Turn clockwise to increase the output volume or turn counterclockwise to decrease the output volume See figure 5 1 Cauti...

Page 14: ...Bosch Security Systems 2008 01 PLE 2CS en Plena Two zone Call Station Installation and User Instructions Operation en 14 Intentionally left blank ...

Page 15: ...atio limiter 1 20 Distortion 0 6 maximum input Equivalent input noise level 25 dB SPL A Frequency response 100 Hz 16 kHz Speech filter 3 dB 315 Hz high pass 6 dB oct Output impedance 200 Ω Type 2x redundant RJ 45 sockets for daisy chaining multiple call stations Base dimensions H x W x D without microphone 40 x 100 x 235 mm 1 57 x 3 97 x 9 25 in Stem length with microphone 390 mm 15 35 in Cat 5 ex...

Page 16: ...Bosch Security Systems 2008 01 PLE 2CS en Plena Two zone Call Station Installation and User Instructions Technical data en 16 Intentionally left blank ...

Page 17: ......

Page 18: ...For more information visit www boschsecuritysystems com Bosch Security Systems B V Data subject to change without notice 2008 01 PLE 2CS en ...

Reviews: