Fault condition
Impact
Open circuit in the main loop
–
No loss of audio.
Short circuit in the main loop
–
Loss of audio in the segment with the short circuit.
Open circuit in the Isolator
Board tap-off
–
Not applicable for this option.
Tap-off overload
–
Not applicable for this option.
Open circuit in the DC Blocking
Board tap-off
–
Loss of audio on the affected DC Blocking Board tap-
off.
Short circuit in the DC Blocking
Board tap-off
–
Loss of audio on the affected DC Blocking Board tap-
off.
Two or more faults on the main
loop and/or DC Blocking Board
tap-off
–
Loss of audio in the affected segments and/or
affected DC Blocking Board tap-offs.
–
Audio artifacts may be present in segments that are
isolated.