No. DIP switch
Description Setting
System status
2
Ground
short Slave
OFF
(default)
–
Use this selection for Praesideo and direct
topology systems (i.e. zones with
independent amplifier channels).
ON
–
Use this selection for Plena Voice Alarm
and bulk switched systems, i.e. systems
that use routers with relays. Multiple
zones share one amplifier and a common
return. For these systems, set one loop
ground short slave switch to OFF, and set
the other loop ground short slave switches
of the Master Unit to ON.
3
Walk Test
OFF
(default)
–
Walk Test mode inactive.
–
Loop OK LED (3) and Connect Fault LED
indication (4) on the rear of Master Unit
are inactive.
–
Refer to Master Unit (rear view), page 47.
ON
–
Walk Test mode active.
–
Loop OK LED (3) and Connect Fault LED
indication (4) on rear of Master Unit are
active.
–
Refer to Master Unit (rear view), page 47.
4
Reserved
OFF
–
Reserved.
ON
–
Reserved.
7
1
Mains
supervision
OFF
(default)
–
Mains fault reporting deactivated (LED and
fault relay).
ON
–
Mains fault reporting activated (LED and
fault relay).
2
Battery
supervision
OFF
(default)
–
Backup fault reporting deactivated (LED
and fault relay).
ON
–
Backup fault reporting activated (LED and
fault relay).
See also
–
42
en | Configuration
Loudspeakers Line Isolator System
2014.03 | V1.1 |
Installation and Operation Manual
Bosch Security Systems B.V.