24
en | General installation procedures and instructions
PRAESENSA
2019.11 | V1.00 |
Installation manual
Bosch Security Systems B.V.
Cable length
Minimum wire cross section [mm
2
]
[m]
[ft]
1000
3280
0.5
0.75
1.5
4
6
6
10
10
16
900
2952
0.5
0.75
1.5
2.5
4
6
10
10
10
800
2624
0.5
0.75
1.5
2.5
4
6
6
10
10
700
2296
0.5
0.5
1
2.5
4
4
6
6
10
600
1968
0.5
0.5
1
2.5
2.5
4
6
6
10
500
1640
0.5
0.5
0.75
1.5
2.5
4
4
6
6
400
1312
0.5
0.5
0.75
1.5
2.5
2.5
4
4
6
300
984
0.5
0.5
0.5
1
1.5
2.5
2.5
2.5
4
250
820
0.5
0.5
0.5
0.75
1.5
1.5
2.5
2.5
4
200
656
0.5
0.5
0.5
0.75
1
1.5
1.5
2.5
4
150
492
0.5
0.5
0.5
0.5
0.75
1
1.5
1.5
2.5
100
328
0.5
0.5
0.5
0.5
0.5
0.75
0.75
1
1.5
50
164
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.75
[W]
@100
V
20
50
100
200
300
400
500
600
-
[W]
@70
V
10
25
50
100
150
200
250
300
400
Loudspeaker power at end‑of‑line
Ethernet copper cable
Notice!
In order to comply with the strict rules regarding compliance to high energy voltage surges on
the Ethernet connections it is mandatory to use shielded twisted pair cabling (F/UTP), not
ordinary unshielded twisted pair cabling (UTP). F/UTP denotes foiled/unshielded twisted pair
and consists of four unshielded twisted pairs encased in an overall foil shield. This is not to
be confused with an S/FTP (screened / foiled twisted pair) cable which has four individually
shielded twisted pairs encased in an overall braided shield.