en | Programming options
PRAESENSA
2021.12.21 | V0.15b | F.01U.402.882
Underwriters Laboratories Listing Document (ULLD)
Bosch Security Systems B.V.
6.4.4
System options
On the System options pages, a number of general, system wide settings can be configured,
such as:
–
Recorded messages
–
System settings
–
Time settings
–
Network supervision
Topic
Configure /
programming
Feature or option
Permitted
in UL2572
(Y/N/
required)
Possible settings
Value
Settings
permitted in
UL2572
System options
(Configuring of
system wide
settings.)
Recorded
messages
Yes
Wav files uploaded with
required audio
.WAV
Wav files
containing
messages
and tones
complying to
UL2572
System settings
General
Yes
Rapid Spanning Tree
Protocol (RSTP)
Enable/disable
Set to enable
Yes
Call station operator
language
Selection of
language
Set to
English
(UL 2572)
Yes
UL amplifier mode
Enable / Disable
Set to enable
Emergency mode
Yes
Disable calls below
priority level
Selection (prio.
0‑224)
Set to 224
Backup power
mode
Yes
Disable calls below
priority level
Selection (prio.
0‑255)
Ancillary
function
Yes
Report mains supply fault Enable/disable
Set to enable
AC power supply
trouble
Yes
Grace time to report
mains fault on control
outputs
Selection: Off /
1 h‑8 h
1 h‑8 h
Alarm sounder
Yes
Reactivate silenced
trouble and emergency
alarm sounder
Selection: Off /
1 h‑24 h
1 h‑24 h
Configuration
software
Yes
Automatic logout after
inactivity of
Selection (5‑30 min.) Set to
30 min.
Time settings
Yes
Set time automatically
(NTP)
Enable/disable
Set to
disable
Network
supervision
Yes
Network supervision
Enable/disable
Set to enable
and make a
snapshot